Table 1. Specifications, Type 7D8J and 7D8K (continued)
Specification
Description
Environment
ThinkSystem ST50 V2 complies with ASHRAE Class A2 specifications.
• Air temperature:
– Operating
– ASHRAE Class A2: 10°C to 35°C (50°F to 95°F); the maximum ambient
temperature decreases by 1°C for every 300 m (984 ft) increase in altitude
above 900 m (2,953 ft).
– Server off: -10°C to 60°C (14°F to 140°F)
– Shipment/storage: -20°C to 60°C (-4°F to 140°F)
• Maximum altitude: 3,050 m (10,000 ft)
• Relative Humidity (non-condensing):
– Operating
– ASHRAE Class A2: 8% to 80%; maximum dew point: 21°C (70°F)
– Shipment/storage: 8% to 90%
• Particulate contamination
Attention:
Airborne particulates and reactive gases acting alone or in combination
with other environmental factors such as humidity or temperature might pose a risk to
the server. For information about the limits for particulates and gases, see
“Particulate contamination” on page 7
.
Operating systems
Supported and certified operating systems:
• Microsoft Windows Server
• VMware ESXi
• Red Hat Enterprise Linux
• SUSE Linux Enterprise Server
• Ubuntu
References:
• Complete list of available operating systems:
.
• OS deployment instructions: See “Deploy the operating system” in
Setup Guide
.
Particulate contamination
Attention:
Airborne particulates (including metal flakes or particles) and reactive gases acting alone or in
combination with other environmental factors such as humidity or temperature might pose a risk to the
device that is described in this document.
Risks that are posed by the presence of excessive particulate levels or concentrations of harmful gases
include damage that might cause the device to malfunction or cease functioning altogether. This
specification sets forth limits for particulates and gases that are intended to avoid such damage. The limits
must not be viewed or used as definitive limits, because numerous other factors, such as temperature or
moisture content of the air, can influence the impact of particulates or environmental corrosives and gaseous
contaminant transfer. In the absence of specific limits that are set forth in this document, you must
implement practices that maintain particulate and gas levels that are consistent with the protection of human
health and safety. If Lenovo determines that the levels of particulates or gases in your environment have
caused damage to the device, Lenovo may condition provision of repair or replacement of devices or parts
on implementation of appropriate remedial measures to mitigate such environmental contamination.
Implementation of such remedial measures is a customer responsibility.
7
Summary of Contents for ThinkSystem ST50 V2
Page 1: ...ThinkSystem ST50 V2 Maintenance Manual Machine Types 7D8J and 7D8K ...
Page 8: ...vi ThinkSystem ST50 V2 Maintenance Manual ...
Page 48: ...40 ThinkSystem ST50 V2 Maintenance Manual ...
Page 122: ...114 ThinkSystem ST50 V2 Maintenance Manual ...
Page 182: ...174 ThinkSystem ST50 V2 Maintenance Manual ...
Page 190: ...182 ThinkSystem ST50 V2 Maintenance Manual ...
Page 191: ......
Page 192: ......