156
NetFn
0x3c
Command
0x12
Request Data:
Byte
Data field
1
Mask Byte
0xFF: Any of below errors will turn on fault led 0x00: Mask
all of errors
The bit description is below:
[7] – PSU Error Mask
[6] – Undetermined Error Mask
[5] – CPU Fault Mask
[4] – Overtemp Mask
[3] – Hightemp Mask
[2] – DIMM Error Mask
[1] – FAN Error Mask
[0] – Sensor Error Mask
Response Data:
Byte
Data field
1
Completion Code
2
Mask – The mask is set
2.18 Get Fault LED Mask
This is the command to get fault led mask.
Linux command:
$ ipmitool raw 0x3c 0x13
Description:
NetFn
0x3c
Command
0x13
Request Data:
Byte
Data field
NONE
NONE
Response Data: