155
1
Status
01h – Turn on fault led
00h – Turn off fault led (Fault led mask will be automatically set to 0x00 to mask all of errors,
user needs to use command 0x12 to set mask to 0xff again so that fault led will works as normal,
see detail in command “Set Fault Led Mask”)
Response Data:
Byte
Data field
1
Completion Code
2
Status
01h: Fault led is turned on
00h: Fault led is turned off
2.16 Get Fault LED Status
This is the command to get fault led status.
Linux command:
$ ipmitool raw 0x3c 0x11
Description:
NetFn
0x3c
Command
0x11
Request Data:
Byte
Data field
NONE
NONE
Response Data:
Byte
Data field
1
Completion Code
2
Status
01h: Fault led is currently on 00h:
Fault led is currently off
2.17 Set Fault LED Mask
This is the command to set fault led mask to enable/disable the error affects fault led.
Linux command:
$ ipmitool raw 0x3c 0x12
Description: