Diagnostic Error Code
FRU/Action
006-197-XXX
Diskette interface test warning
1.
If a component is called out, make sure
it is connected and/or enabled
2.
Re-run test
3.
Replace the component that is called out
in warning statement
4.
Replace the component under test
006-198-XXX
Diskette interface test aborted
1.
If a component is called out, make sure
it is connected and/or enabled
2.
Flash the system and re-test. See “Flash
update procedures” on page 235
3.
Go to “Undetermined problems” on page
86
006-199-XXX
Diskette interface test failed, cause unknown
1.
Go to “Undetermined problems” on page
86
2.
Flash the system and re-test
3.
Replace component under function test
006-25X-XXX
Diskette interface Error
1.
Diskette drive cable
2.
Diskette drive
3.
System board
011-000-XXX
Serial port Interface Test Passed
No action
011-001-XXX
Serial port Presence
1.
Remove external serial device, if
present
2.
Run setup, enable port
3.
System board
011-002-XXX
011-003-XXX
Serial port Timeout/Parity error
System board
011-013-XXX
011-014-XXX
Serial port Control Signal/Loopback test
failure
System board
011-015-XXX
Serial port External Loopback failure
1.
Wrap plug
2.
System board
011-027-XXX
Serial port Configuration/Setup error
1.
Run Setup, enable port
2.
Flash the system. See “Flash update
procedures” on page 235
3.
System board
011-03X-XXX
011-04X-XXX
Serial port failure
System board
011-195-XXX
Serial port Test aborted by user
Information only
Re-start the test, if necessary
011-196-XXX
Serial port test halt, error threshold exceeded
1.
Press F3 to review the log file
2.
Re-start the test to reset the log file
Chapter 8. Symptom-to-FRU Index
67
Summary of Contents for THINKSTATION D10
Page 1: ......
Page 2: ......
Page 3: ...ThinkStation Hardware Maintenance Manual ...
Page 17: ...Chapter 2 Safety information 11 ...
Page 18: ...12 Hardware Maintenance Manual ...
Page 19: ... 18 kg 37 lbs 32 kg 70 5 lbs 55 kg 121 2 lbs 1 2 Chapter 2 Safety information 13 ...
Page 23: ...Chapter 2 Safety information 17 ...
Page 24: ...1 2 18 Hardware Maintenance Manual ...
Page 25: ...Chapter 2 Safety information 19 ...
Page 26: ...1 2 20 Hardware Maintenance Manual ...
Page 33: ...Chapter 2 Safety information 27 ...
Page 34: ...28 Hardware Maintenance Manual ...
Page 35: ...1 2 Chapter 2 Safety information 29 ...
Page 39: ...Chapter 2 Safety information 33 ...
Page 40: ...1 2 34 Hardware Maintenance Manual ...
Page 44: ...38 Hardware Maintenance Manual ...
Page 54: ...48 Hardware Maintenance Manual ...
Page 58: ...52 Hardware Maintenance Manual ...
Page 64: ...58 Hardware Maintenance Manual ...
Page 94: ...88 Hardware Maintenance Manual ...
Page 103: ...Chapter 9 Replacing FRUs types 6423 and 6483 97 ...
Page 106: ...100 Hardware Maintenance Manual ...
Page 130: ...124 Hardware Maintenance Manual ...
Page 140: ...134 Hardware Maintenance Manual ...
Page 158: ...8 Go to Completing the FRU replacement on page 158 152 Hardware Maintenance Manual ...
Page 247: ......
Page 248: ...Part Number 43C9807 Printed in USA 1P P N 43C9807 ...