Figure 15. 2.5-inch hot-swap hard disk drive status LEDs
1
Hard disk drive activity LED
2
Hard disk drive RAID status LED
Description
Off
Off
The hard disk drive has failed or is
not present.
On, green
Off
The hard disk drive is present but not
in use.
Blinking, green
Off
The hard disk drive is active and data
is being transferred.
On, green
Blinking rapidly (about four flashes
per second), amber
The RAID controller is locating the
hard disk drive.
On, green
On, amber
The RAID array has failed and cannot
recover.
Blinking, green
Blinking slowly (about one flash per
second), amber
The hard disk drive is being rebuilt.
RAID card
This topic provides information to help you locate the connectors on a RAID card if a RAID card is installed in
the PCI-E slot 1 on the system board. See “System board components” on page 37.
28
ThinkServer TS440 User Guide
Summary of Contents for ThinkServer TS440
Page 1: ...ThinkServer TS440 User Guide Machine Types 70AL 70AM 70AN and 70AQ ...
Page 16: ...4 ThinkServer TS440 User Guide ...
Page 18: ...6 ThinkServer TS440 User Guide ...
Page 56: ...44 ThinkServer TS440 User Guide ...
Page 74: ...62 ThinkServer TS440 User Guide ...
Page 166: ...154 ThinkServer TS440 User Guide ...
Page 176: ...164 ThinkServer TS440 User Guide ...
Page 181: ......
Page 182: ......