SNMP Trap ID
50
CIM Information
Prefix:
PLAT
ID:
0245
User Response
1. (Trained technician only) Replace microprocessor n (see Removing a microprocessor and heat
sink and Replacing a microprocessor and heat sink).
2. If the problem persists and there is no other CPU with the same error indication, replace the
system board.
3. (Trained technician only) Replace the system board (see Removing the system board and
Replacing the system board). (n = microprocessor number)
IMM Events that automatically notify Support
You can configure the IBM Flex System Manager or the CMM to automatically notify Support (also known as
call home
) if certain types of errors are encountered. If you have configured this function, see the table for
a list of events that automatically notify Support.
Table 39. Events that automatically notify Support
Event ID
Message String
Automatically
Notify Support
40000086-00000000
Test Call Home Generated by user [arg1].
Yes
40000087-00000000
Manual Call Home by user [arg1]: [arg2].
Yes
80010202-0701ffff
Numeric sensor [NumericSensorElementName] going low
(lower critical) has asserted.
Yes
80010902-0701ffff
Numeric sensor [NumericSensorElementName] going
high (upper critical) has asserted.
Yes
806f0021-2201ffff
Fault in slot [PhysicalConnectorSystemElementName] on
system [ComputerSystemElementName]. (No Op ROM
Space)
Yes
806f0021-2582ffff
Fault in slot [PhysicalConnectorSystemElementName] on
system [ComputerSystemElementName]. (All PCI Error)
Yes
806f0021-3001ffff
Fault in slot [PhysicalConnectorSystemElementName] on
system [ComputerSystemElementName]. (PCI 1)
Yes
806f0021-3002ffff
Fault in slot [PhysicalConnectorSystemElementName] on
system [ComputerSystemElementName]. (PCI 2)
Yes
806f0021-3003ffff
Fault in slot [PhysicalConnectorSystemElementName] on
system [ComputerSystemElementName]. (PCI 3)
Yes
806f0021-3004ffff
Fault in slot [PhysicalConnectorSystemElementName] on
system [ComputerSystemElementName]. (PCI 4)
Yes
806f0021-3005ffff
Fault in slot [PhysicalConnectorSystemElementName] on
system [ComputerSystemElementName]. (PCI 5)
Yes
806f0021-3006ffff
Fault in slot [PhysicalConnectorSystemElementName] on
system [ComputerSystemElementName]. (PCI 6)
Yes
Appendix A. Integrated Management Module II (IMM2) error messages
955
Summary of Contents for System x3500 M4
Page 1: ...System x3500 M4 Installation and Service Guide Machine Type 7383 ...
Page 6: ...iv System x3500 M4 Installation and Service Guide ...
Page 14: ...xii System x3500 M4 Installation and Service Guide ...
Page 140: ...126 System x3500 M4 Installation and Service Guide ...
Page 180: ...166 System x3500 M4 Installation and Service Guide ...
Page 194: ...180 System x3500 M4 Installation and Service Guide ...
Page 978: ...964 System x3500 M4 Installation and Service Guide ...
Page 1002: ...988 System x3500 M4 Installation and Service Guide ...
Page 1160: ...1146 System x3500 M4 Installation and Service Guide ...
Page 1164: ...1150 System x3500 M4 Installation and Service Guide ...
Page 1172: ...Taiwan BSMI RoHS declaration 1158 System x3500 M4 Installation and Service Guide ...
Page 1181: ......
Page 1182: ......