Hinge
Figure 152. Position the top of the USB cable
Step 10. Connect the USB and light path diagnostics cable to the system board (see “System-board internal
connectors” on page 27 and “Internal cable routing and connectors” on page 312).
Step 11. Install the fan cage assembly (see “Installing the fan cage assembly” on page 274).
Step 12. Install the air baffle (see “Installing the air baffle” on page 190).
Step 13. Install the hot-swap power supply or power supplies (see “Installing a hot-swap power supply” on
Step 14. Install the bezel (see “Installing the bezel” on page 187).
Step 15. Install and lock the left-side cover (see “Installing the left-side cover” on page 185).
If you have replaced a server component or installed an optional device in the server, you need to reconnect
the power cords and all external cables, and turn on the server and peripheral devices.
Removing the light path diagnostics assembly
Use the information to remove the light path diagnostics assembly.
Read the safety information in “Safety” on page v and “Installation guidelines” on page 35.
If you are replacing a server component in the server, you need to turn off the server and peripheral devices,
and disconnect the power cords and all external cables.
To remove the light path diagnostics assembly from the server, complete the following steps.
Step 1.
Carefully lay the server down on its side.
Step 2.
Unlock and remove the left-side cover (see “Removing the left-side cover” on page 184).
Step 3.
Remove the air baffle (see “Removing the air baffle” on page 189).
Step 4.
Remove the fan cage assembly (see “Removing the fan cage assembly” on page 272).
Step 5.
Disconnect the light path diagnostics cable from the system board (see “System-board internal
connectors” on page 27 and “Internal cable routing and connectors” on page 312).
Step 6.
Stand the server back up in its vertical position.
Removing and replacing components
239
Summary of Contents for System x3500 M4
Page 1: ...System x3500 M4 Installation and Service Guide Machine Type 7383 ...
Page 6: ...iv System x3500 M4 Installation and Service Guide ...
Page 14: ...xii System x3500 M4 Installation and Service Guide ...
Page 140: ...126 System x3500 M4 Installation and Service Guide ...
Page 180: ...166 System x3500 M4 Installation and Service Guide ...
Page 194: ...180 System x3500 M4 Installation and Service Guide ...
Page 978: ...964 System x3500 M4 Installation and Service Guide ...
Page 1002: ...988 System x3500 M4 Installation and Service Guide ...
Page 1160: ...1146 System x3500 M4 Installation and Service Guide ...
Page 1164: ...1150 System x3500 M4 Installation and Service Guide ...
Page 1172: ...Taiwan BSMI RoHS declaration 1158 System x3500 M4 Installation and Service Guide ...
Page 1181: ......
Page 1182: ......