Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Warning - Redundant Power Supply
SNMP Trap ID
10
CIM Information
Prefix:
PLAT
ID:
0807
User Response
No action; information only.
•
810b030c-2581ffff : Non-redundant:Sufficient Resources from Redundancy Degraded or Fully
Redundant for [RedundancySetElementName] has deasserted. (Backup Memory)
This message is for the use case when a Redundancy Set has transitioned from Non-redundant:Sufficient
Resources.
May also be shown as 810b030c2581ffff or 0x810b030c2581ffff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Warning - Memory
SNMP Trap ID
43
CIM Information
Prefix:
PLAT
ID:
0807
User Response
No action; information only.
•
810b0509-1301ffff : Non-redundant:Insufficient Resources for [RedundancySetElementName]
has deasserted. (Power Resource)
This message is for the use case when a Redundancy Set has transitioned from Non-redundant:Insufficient
Resources.
May also be shown as 810b05091301ffff or 0x810b05091301ffff
Appendix A. Integrated Management Module II (IMM2) error messages
743
Summary of Contents for System x3500 M4
Page 1: ...System x3500 M4 Installation and Service Guide Machine Type 7383 ...
Page 6: ...iv System x3500 M4 Installation and Service Guide ...
Page 14: ...xii System x3500 M4 Installation and Service Guide ...
Page 140: ...126 System x3500 M4 Installation and Service Guide ...
Page 180: ...166 System x3500 M4 Installation and Service Guide ...
Page 194: ...180 System x3500 M4 Installation and Service Guide ...
Page 978: ...964 System x3500 M4 Installation and Service Guide ...
Page 1002: ...988 System x3500 M4 Installation and Service Guide ...
Page 1160: ...1146 System x3500 M4 Installation and Service Guide ...
Page 1164: ...1150 System x3500 M4 Installation and Service Guide ...
Page 1172: ...Taiwan BSMI RoHS declaration 1158 System x3500 M4 Installation and Service Guide ...
Page 1181: ......
Page 1182: ......