Attention:
Static electricity that is released to internal server components when the server is powered-on
might cause the server to stop, which might result in the loss of data. To avoid this potential problem,
always use an electrostatic-discharge wrist strap or other grounding system when working inside the
server with the power on.
Read the safety information in “Safety” on page v and “Installation guidelines” on page 35.
If you are replacing a server component in the server, you need to turn off the server and peripheral devices,
and disconnect the power cords and all external cables.
To install an adapter, complete the following steps.
Step 1.
Carefully turn the server on its side so that it is lying flat, with the cover facing up.
Attention:
Do not allow the server to fall over.
Step 2.
Unlock and remove the left-side cover (see “Removing the left-side cover” on page 184).
Step 3.
See the documentation that comes with the adapter for any cabling instructions and information
about jumper or switch settings. (It might be easier for you to route cables before you install
the adapter.)
Step 4.
Touch the static-protective package that contains the adapter to any unpainted metal surface on
the server; then, remove the adapter from the package.
Step 5.
Determine the PCI slot into which you will install the adapter.
Step 6.
Rotate the adapter-retention brackets to the open position.
0000
0000
0000
00
00
00
000
000
000
000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
Figure 131. Rotate the adapter-retention brackets to the open position
Step 7.
Remove the PCI slot filler, if installed. Keep the filler in a safe place for potential future use.
Step 8.
Press the adapter
firmly
into the expansion slot.
Removing and replacing components
217
Summary of Contents for System x3500 M4
Page 1: ...System x3500 M4 Installation and Service Guide Machine Type 7383 ...
Page 6: ...iv System x3500 M4 Installation and Service Guide ...
Page 14: ...xii System x3500 M4 Installation and Service Guide ...
Page 140: ...126 System x3500 M4 Installation and Service Guide ...
Page 180: ...166 System x3500 M4 Installation and Service Guide ...
Page 194: ...180 System x3500 M4 Installation and Service Guide ...
Page 978: ...964 System x3500 M4 Installation and Service Guide ...
Page 1002: ...988 System x3500 M4 Installation and Service Guide ...
Page 1160: ...1146 System x3500 M4 Installation and Service Guide ...
Page 1164: ...1150 System x3500 M4 Installation and Service Guide ...
Page 1172: ...Taiwan BSMI RoHS declaration 1158 System x3500 M4 Installation and Service Guide ...
Page 1181: ......
Page 1182: ......