Figure 144. The available fan sockets in the server
2. You can order the three additional fans for redundant cooling.
Read the safety information in “Safety” on page v and “Installation guidelines” on page 35.
Attention:
Static electricity that is released to internal server components when the server is powered-on
might cause the server to halt, which might result in the loss of data. To avoid this potential problem,
always use an electrostatic-discharge wrist strap or other grounding system when you work inside the
server with the power on.
If you are replacing a server component in the server, you need to turn off the server and peripheral devices,
and disconnect the power cords and all external cables.
To install a simple-swap fan, complete the following steps.
Step 1.
Touch the static-protective package that contains the simple-swap fan to any unpainted metal
surface on the server; then, remove the fan from the package.
Step 2.
Unlock and remove the left-side cover (see “Removing the left-side cover” on page 184).
Step 3.
Open the fan cage cover.
Step 4.
Perform the following steps only if you want to install the simple swap fan in the Fan 2 compartment:
a.
Unfasten and open the release lever (see “Removing the fan cage assembly” on page 272).
b.
Press and release the clip on the fan filler to remove the fan filler from the server.
Removing and replacing components
231
Summary of Contents for System x3500 M4
Page 1: ...System x3500 M4 Installation and Service Guide Machine Type 7383 ...
Page 6: ...iv System x3500 M4 Installation and Service Guide ...
Page 14: ...xii System x3500 M4 Installation and Service Guide ...
Page 140: ...126 System x3500 M4 Installation and Service Guide ...
Page 180: ...166 System x3500 M4 Installation and Service Guide ...
Page 194: ...180 System x3500 M4 Installation and Service Guide ...
Page 978: ...964 System x3500 M4 Installation and Service Guide ...
Page 1002: ...988 System x3500 M4 Installation and Service Guide ...
Page 1160: ...1146 System x3500 M4 Installation and Service Guide ...
Page 1164: ...1150 System x3500 M4 Installation and Service Guide ...
Page 1172: ...Taiwan BSMI RoHS declaration 1158 System x3500 M4 Installation and Service Guide ...
Page 1181: ......
Page 1182: ......