Chapter 7. Configuring RAID
This chapter provides information about storage drive requirements for Redundant Array of Independent
Disks (RAID) levels, and instructions on how to configure RAID for your computer.
An Introduction to RAID
RAID is a technology that provides increased storage functions and reliability through redundancy.
When a group of independent physical storage drives is set up to use RAID technology, they are in a RAID
array. This array distributes data across multiple storage drives, but the array appears to the host computer
as one single storage unit. Creating and using RAID arrays provides high performance, such as the expedited
I/O performance, because several drives can be accessed simultaneously.
RAID drive groups configured according to certain RAID levels also improve data storage reliability and fault
tolerance compared with single-drive storage systems. Data loss resulting from a drive failure can be
prevented by reconstructing missing data from the remaining drives.
Note:
For RAID 0, the missing data resulting from a drive failure cannot be reconstructed.
Storage drive requirements for RAID levels
Your computer supports the following internal storage drives:
• 2.5-inch form factor, 7-mm (0.28-inch) height hard disk drive
• M.2 Serial Advanced Technology Attachment (SATA) solid-state drive (available on some models)
• M.2 Non-Volatile Memory Express (NVMe) solid-state drive (available on some models)
Note:
Ensure that your computer has two identical storage drives installed (two hard disk drives, M.2 SATA
solid-state drives, or M.2 NVMe solid-state drives with the same capacity) for supported RAID levels. If only
one drive is installed, or two different types of drives are installed, the following information does not apply.
Your computer supports the following RAID levels:
• RAID 0: striped disk array
– Consists of two identical storage drives
– Supported strip size: 4 KB, 8 KB, 16 KB, 32 KB, 64 KB, or 128 KB
– Better performance without fault tolerance
– Higher risk of data loss resulting from a member drive failure compared with non-RAID configuration
• RAID 1: mirrored disk array
– Consists of two identical storage drives
– Improved reading performance and 100% redundancy
Configuring RAID with the Intel RST configuration utility
This topic provides the following instructions to help you configure RAID with the Intel RST configuration
utility:
• How to enter the Intel RST configuration utility
• How to create RAID volumes
© Copyright Lenovo 2015, 2017
83
Summary of Contents for P70
Page 1: ...P70 User Guide ...
Page 6: ...iv P70 User Guide ...
Page 56: ...38 P70 User Guide ...
Page 64: ...46 P70 User Guide ...
Page 70: ...52 P70 User Guide ...
Page 78: ...60 P70 User Guide ...
Page 122: ...104 P70 User Guide ...
Page 130: ...112 P70 User Guide ...
Page 156: ...138 P70 User Guide ...
Page 160: ...142 P70 User Guide ...
Page 162: ...144 P70 User Guide ...
Page 174: ...156 P70 User Guide ...
Page 175: ...Taiwan RoHS Appendix D Restriction of Hazardous Substances RoHS Directive 157 ...
Page 176: ...158 P70 User Guide ...
Page 182: ...164 P70 User Guide ...
Page 183: ......
Page 184: ......