This section provides instructions on how to replace the cover presence switch (intrusion switch). This topic
applies only to server models that have the cover presence switch installed.
Note:
Depending on the model, your server might look slightly different from the illustrations in this topic.
To replace the cover presence switch, do the following:
1. Remove all media from the drives and turn off all attached devices and the server. Then, disconnect all
power cords from electrical outlets and disconnect all cables that are connected to the server.
2. Remove the server cover. See “Removing the server cover” on page 67.
3. Locate the cover presence switch. See “Server components” on page 22.
4. Disconnect the cable of the cover presence switch from the cover presence switch connector on the
system board. See “System board components” on page 38.
5. Remove the screw that secures the cover presence switch assembly. Then, push the cover presence
switch assembly to the front of the chassis until it is released from the chassis, and then remove
it out of the chassis.
Figure 78. Removing the cover presence switch assembly
126
ThinkServer TS440 Hardware Maintenance Manual
Summary of Contents for 70AL
Page 1: ...ThinkServer TS440 Hardware Maintenance Manual Machine Types 70AL 70AM 70AN and 70AQ ...
Page 16: ...4 ThinkServer TS440 Hardware Maintenance Manual ...
Page 18: ...6 ThinkServer TS440 Hardware Maintenance Manual ...
Page 56: ...44 ThinkServer TS440 Hardware Maintenance Manual ...
Page 58: ...46 ThinkServer TS440 Hardware Maintenance Manual ...
Page 76: ...64 ThinkServer TS440 Hardware Maintenance Manual ...
Page 174: ...162 ThinkServer TS440 Hardware Maintenance Manual ...
Page 184: ...172 ThinkServer TS440 Hardware Maintenance Manual ...
Page 189: ......
Page 190: ......