4. The non-hot-swap hard disk drives are installed in the lower hard disk drive cage and are protected
by an EMI-protective panel. Press the small tab
1
on the EMI-protective panel from the bottom, and
then pivot the EMI-protective panel upward to remove it from the chassis and gain access to the
non-hot-swap hard disk drives.
Figure 55. Removing the EMI-protective panel
5. Remove the front system fan 1. See “Replacing the front system fan 1” on page 130.
6. Locate the non-hot-swap hard disk drive. See “Server components” on page 22. Then, disconnect the
SATA signal cable and the power cable from the rear of the non-hot-swap hard disk drive.
Chapter 6
.
Installing, removing, or replacing hardware