9. Do one of the following:
• For the backplane for server models with 3.5-inch hard disk drive bays, remove the four screws that
secure the backplane, and then remove the backplane from the hard disk drive cage.
Figure 70. Removing the backplane for server models with 3.5-inch hard disk drive bays
• For the backplane for server models with 2.5-inch hard disk drive bays, remove the six screws or
three screws that secure the backplane depending on the type of the backplane. Then, remove
the backplane from the hard disk drive cage.
Figure 71. Removing the backplane for server models with 2.5-inch hard disk drive bays
10. Touch the static-protective package that contains the new hot-swap hard disk drive backplane to any
unpainted surface on the outside of the server. Then, remove the new backplane from the package.
Note:
Carefully handle the backplane by its edges.
11. Position the new backplane on the hard disk drive cage so that the screw holes in the new backplane
are aligned with the corresponding holes in the hard disk drive cage. Then, do one of the following
depending on the hard disk drive cage:
120
ThinkServer TS440 Hardware Maintenance Manual
Summary of Contents for 70AL
Page 1: ...ThinkServer TS440 Hardware Maintenance Manual Machine Types 70AL 70AM 70AN and 70AQ ...
Page 16: ...4 ThinkServer TS440 Hardware Maintenance Manual ...
Page 18: ...6 ThinkServer TS440 Hardware Maintenance Manual ...
Page 56: ...44 ThinkServer TS440 Hardware Maintenance Manual ...
Page 58: ...46 ThinkServer TS440 Hardware Maintenance Manual ...
Page 76: ...64 ThinkServer TS440 Hardware Maintenance Manual ...
Page 174: ...162 ThinkServer TS440 Hardware Maintenance Manual ...
Page 184: ...172 ThinkServer TS440 Hardware Maintenance Manual ...
Page 189: ......
Page 190: ......