Diagnostic Error Code
FRU/Action
005-2XX-XXX 005-3XX-XXX
Video subsystem error
1.
Video card, if installed
2. System board
006-000-XXX
Diskette interface Test Passed
No action
006-0XX-XXX
Diskette interface error
1.
Diskette drive Cable
2. Diskette drive
3. System board
006-195-XXX
Diskette interface Test aborted by user
Information only
Re-start the test, if necessary
006-196-XXX
Diskette interface test halt, error threshold
exceeded
1.
Press F3 to review the log file
2. Re-start the test to reset the log file
006-197-XXX
Diskette interface test warning
1.
If a component is called out, make sure it is
connected and/or enabled
2. Re-run test
3. Replace the component that is called out in warning
statement
4. Replace the component under test
006-198-XXX
Diskette interface test aborted
1.
If a component is called out, make sure it is
connected and/or enabled
2. Flash the system and re-test. See “Flash update
procedures” on page 259
3. Go to “Undetermined problems” on page 73
006-199-XXX
Diskette interface test failed, cause
unknown
1. Go to “Undetermined problems” on page 73
2. Flash the system and re-test
3. Replace component under function test
006-25X-XXX
Diskette interface Error
1.
Diskette drive cable
2. Diskette drive
3. System board
011-000-XXX
Serial port Interface Test Passed
No action
011-001-XXX
Serial port Presence
1.
Remove external serial device, if present
2. Run setup, enable port
3. System board
011-002-XXX 011-003-XXX
Serial port Timeout/Parity
error
System board
011-013-XXX 011-014-XXX
Serial port Control
Signal/Loopback test failure
System board
011-015-XXX
Serial port External Loopback failure
1.
Wrap plug
2. System board
011-027-XXX
Serial port Configuration/Setup error
1.
Run Setup, enable port
2. Flash the system. See “Flash update procedures” on
page 259
3. System board
011-03X-XXX 011-04X-XXX
Serial port failure
System board
011-195-XXX
Serial port Test aborted by user
Information only
Re-start the test, if necessary
Chapter 9
.
Symptom-to-FRU Index
57
Summary of Contents for 4157 - ThinkStation S20 - 2 GB RAM
Page 1: ...ThinkStation Hardware Maintenance Manual Machine Type 4105 4155 4157 4158 4217 4218 ...
Page 2: ......
Page 3: ...ThinkStation Hardware Maintenance Manual Machine Type 4105 4155 4157 4158 4217 4218 ...
Page 15: ...Chapter 2 Safety information 9 ...
Page 19: ...Chapter 2 Safety information 13 ...
Page 20: ...1 2 14 ThinkStation Hardware Maintenance Manual ...
Page 21: ...Chapter 2 Safety information 15 ...
Page 27: ...Chapter 2 Safety information 21 ...
Page 31: ...Chapter 2 Safety information 25 ...
Page 38: ...32 ThinkStation Hardware Maintenance Manual ...
Page 56: ...50 ThinkStation Hardware Maintenance Manual ...
Page 80: ...74 ThinkStation Hardware Maintenance Manual ...
Page 93: ...Chapter 10 Replacing FRUs Type 4105 4157 4217 87 ...
Page 124: ...118 ThinkStation Hardware Maintenance Manual ...
Page 264: ...258 ThinkStation Hardware Maintenance Manual ...
Page 268: ...262 ThinkStation Hardware Maintenance Manual ...
Page 274: ...268 ThinkStation Hardware Maintenance Manual ...
Page 275: ......
Page 276: ...Part Number 53Y4348 Printed in USA 1P P N 53Y4348 53Y4348 ...