Diagnostic Error Code
FRU/Action
001-273-XXX
System IRQ6 (diskette drive) failure
1.
Diskette Cable
2. Diskette drive
3. System board
001-274-XXX
System IRQ7 failure
1.
Device on IRQ7
2. System board
001-275-XXX
System IRQ8 failure
1.
Device on IRQ8
2. System board
001-276-XXX
System IRQ9 failure
1.
Device on IRQ9
2. System board
001-277-XXX
System IRQ10 failure
1.
Device on IRQ10
2. System board
001-278-XXX
System IRQ11 failure
1.
Device on IRQ11
2. System board
001-279-XXX
System IRQ12 failure
1.
Device on IRQ12
2. System board
001-280-XXX
System IRQ13 failure
1.
Device on IRQ13
2. System board
001-281-XXX
System IRQ14 (hard disk drive) failure
1.
Hard disk drive cable
2. Hard disk drive
3. System board
001-282-XXX
System IRQ15 failure
1.
Device on IRQ15
2. System board
001-286-XXX 001-287-XXX 001-288-XXX
System Timer
failure
System board
001-292-XXX
System CMOS RAM error
1.
Run Setup and re-test
2. System board
001-293-XXX
System CMOS Battery
1.
CMOS Battery
2. System board
001-298-XXX
System RTC date/time update failure
1.
Flash the system. See “Flash update procedures”
on page 259
2. System board
001-299-XXX
System RTC periodic interrupt failure
System board
001-300-XXX
System RTC Alarm failure
System board
001-301-XXX
System RTC Century byte error
1.
Flash the system. See “Flash update procedures”
on page 259
2. System board
005-000-XXX
Video Test Passed
No action
005-00X-XXX
Video error
1.
Video card, if installed
2. System board
005-010-XXX 005-011-XXX 005-012-XXX 005-013-XXX
Video Signal failure
1.
Video card, if installed
2. System board
Chapter 9
.
Symptom-to-FRU Index
55
Summary of Contents for 4157 - ThinkStation S20 - 2 GB RAM
Page 1: ...ThinkStation Hardware Maintenance Manual Machine Type 4105 4155 4157 4158 4217 4218 ...
Page 2: ......
Page 3: ...ThinkStation Hardware Maintenance Manual Machine Type 4105 4155 4157 4158 4217 4218 ...
Page 15: ...Chapter 2 Safety information 9 ...
Page 19: ...Chapter 2 Safety information 13 ...
Page 20: ...1 2 14 ThinkStation Hardware Maintenance Manual ...
Page 21: ...Chapter 2 Safety information 15 ...
Page 27: ...Chapter 2 Safety information 21 ...
Page 31: ...Chapter 2 Safety information 25 ...
Page 38: ...32 ThinkStation Hardware Maintenance Manual ...
Page 56: ...50 ThinkStation Hardware Maintenance Manual ...
Page 80: ...74 ThinkStation Hardware Maintenance Manual ...
Page 93: ...Chapter 10 Replacing FRUs Type 4105 4157 4217 87 ...
Page 124: ...118 ThinkStation Hardware Maintenance Manual ...
Page 264: ...258 ThinkStation Hardware Maintenance Manual ...
Page 268: ...262 ThinkStation Hardware Maintenance Manual ...
Page 274: ...268 ThinkStation Hardware Maintenance Manual ...
Page 275: ......
Page 276: ...Part Number 53Y4348 Printed in USA 1P P N 53Y4348 53Y4348 ...