Chapter 7. Installing hard disk drives and configuring RAID
(types 4105, 4157, 4217)
This chapter contains information about installing hard disk drives and configuring Redundant Array of
Independent Disks (RAID) for this product.
Note:
The information about configuring RAID in this chapter is applicable only for a Windows environment.
For information about configuring RAID in a Linux environment, contact your Linux software provider.
Installing SATA hard disk drives and configuring RAID
This section contains information about the required number of SATA hard disk drives for the supported level
of RAID and SATA RAID configuration.
Installing SATA hard disk drives
Your computer must have the minimum number of SATA hard disk drives installed for the supported level of
RAID below:
• RAID Level 0 – Striped disk array
– Two hard disk drives minimum
– Better performance without fault tolerance
• RAID Level 1 – Mirrored disk array
– Two hard disk drives minimum
– Improved read performance and 100% redundancy
• RAID Level 5 – Block-level striped disk array with distributed parity
– Three hard disk drives minimum
– Data striped at the byte level
– Stripe error correction information
– Better performance and fault tolerance
To install a new SATA hard disk drive, refer to the installation procedure in “Replacing a hard disk drive” in
the
ThinkStation Hardware Installation and Replacement Guide
.
Configuring the system BIOS to enable SATA RAID functionality
This section describes how to configure the system BIOS to enable SATA RAID functionality.
Note:
Use the arrow keys on the keyboard to make selections.
1. Press F1 to enter the system BIOS setup. See “Starting the Setup Utility program ” on page 39.
2. Select
Devices
®
IDE Drives Setup
and press Enter.
3. Select
SATA RAID Enable
and press Enter.
4. Select
Enabled
and press Enter.
5. Press F10 to save the new settings and exit.
© Copyright Lenovo 2008, 2010
43
Summary of Contents for 4157 - ThinkStation S20 - 2 GB RAM
Page 1: ...ThinkStation Hardware Maintenance Manual Machine Type 4105 4155 4157 4158 4217 4218 ...
Page 2: ......
Page 3: ...ThinkStation Hardware Maintenance Manual Machine Type 4105 4155 4157 4158 4217 4218 ...
Page 15: ...Chapter 2 Safety information 9 ...
Page 19: ...Chapter 2 Safety information 13 ...
Page 20: ...1 2 14 ThinkStation Hardware Maintenance Manual ...
Page 21: ...Chapter 2 Safety information 15 ...
Page 27: ...Chapter 2 Safety information 21 ...
Page 31: ...Chapter 2 Safety information 25 ...
Page 38: ...32 ThinkStation Hardware Maintenance Manual ...
Page 56: ...50 ThinkStation Hardware Maintenance Manual ...
Page 80: ...74 ThinkStation Hardware Maintenance Manual ...
Page 93: ...Chapter 10 Replacing FRUs Type 4105 4157 4217 87 ...
Page 124: ...118 ThinkStation Hardware Maintenance Manual ...
Page 264: ...258 ThinkStation Hardware Maintenance Manual ...
Page 268: ...262 ThinkStation Hardware Maintenance Manual ...
Page 274: ...268 ThinkStation Hardware Maintenance Manual ...
Page 275: ......
Page 276: ...Part Number 53Y4348 Printed in USA 1P P N 53Y4348 53Y4348 ...