7 Maintenance, Troubleshooting
Bauer
58
GEL 2444
E
nglis
h
7 Maintenance,
Troubleshooting
The MiniCODER does not contain any moving parts and is therefore largely mainte-
nance-free.
Maintenance
When?
What?
MiniCODER faulty
►
Replace the MiniCODER.
Regularly
►
Check the MiniCODER for damage.
►
Make sure there are no foreign bodies in the installation
space for the MiniCODER.
►
Clean the MiniCODER with water or a non-corrosive clean-
ing agent.
Do not use a high pressure cleaner.
Troubleshooting
Malfunction
Possible causes
Remedy
No output signal or
erroneous output
signal
Electrical connection faulty
Check all electrical connections
between MiniCODER and pow-
er supply, as well as the evalu-
ation electronics for correct-
ness and secure contact, and
ensure they are dry.
Incorrect air gap between
measuring surface and tar-
get wheel
Check whether the required
value is maintained in all (cli-
matic) conditions over a com-
plete tooth wheel revolution.
Using a torque wrench, check
whether the fastening screws
are correctly tightened.
Measuring surface of target
wheel damaged
Replace the damaged compo-
nent.
Determine the cause of the
damage and rectify it.
Counting direction
incorrect
Track assignment incorrect
Check the connections for the
track signals and change them
if necessary (direction of rota-
tion assignment:
)