5 Mounting and connection
Bauer
Connecting MiniCODER electrically
56
GEL 2444
E
nglis
h
5.3.3 Checking
function
The MiniCODER
GEL 2444K
␣
P
␣␣␣␣␣␣␣
can be adjusted, analysed and
configured using the testing and programming unit GEL 211.
Check the function of the MiniCODER using a suitable instrument, preferably an
oscilloscope.
Connect the MiniCODER to the instrument (
ff).
Connect the MiniCODER to the power supply (
ff).
Switch on the power supply.
Slowly rotate the target wheel and monitor the output signal on the instrument.
If function is correct an adequate sine wave or square-wave signal will be displayed
on the oscilloscope (
Switch off the power supply.
Remove the instrument and the power supply.
5.3.4 Completing
mounting
►
After a successful function test, tighten the two mounting screws to the torque of
max. 2.5 Nm.
M
5.4
Connecting MiniCODER electrically
Pay attention to the minimum bending radius so that the connection
cable is not damaged by excessive bending (
Observe the instructions on electromagnetic compatibility while laying the cables
(
f).
Correctly connect the MiniCODER as per the pin layout (
ff).