Page 51
TABLE 24 Continued
Maximum Allowable Intake or Exhaust Vent Length in Feet
*Size intake and exhaust pipe length separately. Values in table are for Intake OR Exhaust, not combined total. Both Intake and Exhaust m
ust be same pipe size.
NOTE - Additional vent pipe and elbows used to terminate the vent pipe outside the structure must be included in the total vent length calculation
Concentric Termination 0 - 7501”
Number
of 90̊
Elbows
Used
1-1/2” Pipe
2” Pipe
2-1/2” Pipe
3” Pipe
Model
Model
Model
Model
070 090 110
135
070
090
110 135 070 090 110 135 070 090
110
135
1
15
N/A N/A N/A
83
67
12
N/A
130
89
39
N/A
146 139
114
105
2
10
78
62
7
125
84
34
141 134
109
100
3
N/A
73
57
N/A
120
79
29
136 129
104
95
4
68
52
115
74
24
131 124
99
90
5
63
47
110
69
19
126
119
94
85
6
58
42
105
64
14
121
114
89
80
7
53
37
100
59
N/A
116
109
84
75
8
48
32
95
54
111
104
79
70
9
43
27
90
49
106
99
74
65
10
38
22
85
44
101
94
69
60
Concentric Termination 7501” - 10,000”
Number
of 90̊
Elbows
Used
1-1/2” Pipe
2” pipe
2-1/2” Pipe
3” Pipe
Model
Model
Model
Model
070 090 110
135
070
090
110 135 070 090 110 135 070 090
110
135
1
10
N/A N/A N/A
58
42
N/A N/A
105
64
N/A N/A
121
114
89
80
2
N/A
53
37
100
59
116
109
84
75
3
48
32
95
54
111
104
79
70
4
43
27
90
49
106
99
74
65
5
38
22
85
44
101
94
69
60
6
33
17
80
39
96
89
64
55
7
28
12
75
34
91
84
59
50
8
23
N/A
70
29
86
79
54
45
9
18
65
24
81
74
49
40
10
13
60
19
76
69
44
35