background image

07/06

504,953M

*2P0706*

*P504953M*

Page 1

2006 Lennox Industries Inc.

Dallas, Texas, USA

RETAIN THESE INSTRUCTIONS

FOR FUTURE REFERENCE

WARNING

Improper installation, adjustment, alteration, ser-
vice or maintenance can cause property damage,
personal injury or loss of life. Installation and ser-
vice must be performed by a qualified installer or
service agency.

CAUTION

Physical contact with metal edges and corners
while applying excessive force or rapid motion can
result in personal injury. Be aware of, and use
caution when working near these areas during
installation or while servicing this equipment.

IMPORTANT

This unit must be matched with an indoor coil as
specified in Lennox’ Engineering Handbook.
Coils previously charged with HCFC−22 must be
flushed.

IMPORTANT

The Clean Air Act of 1990 bans the intentional vent-
ing of refrigerant (CFC’s, HCFC’s AND HFC’s) as of
July 1, 1992. Approved methods of recovery, recycl-
ing or reclaiming must be followed. Fines and/or in-
carceration may be levied for noncompliance.

INSTALLATION
INSTRUCTIONS

HSXA16

 

Series Units

CONDENSING UNITS

504,953M
07/06
Supersedes 03/06

Table of Contents

HSXA16 Outdoor Unit

1

. . . . . . . . . . . . . . . . . . . . . . . . . . 

Shipping & Packing List

1

. . . . . . . . . . . . . . . . . . . . . . . . 

General Information

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . 

Unit Dimensions

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Setting The Unit

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Electrical

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Refrigerant Piping

5

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Refrigerant Metering Device

8

. . . . . . . . . . . . . . . . . . . . 

Flushing Existing Line Set & Indoor Coil

8

. . . . . . . . . . 

Manifold Gauge Set

9

. . . . . . . . . . . . . . . . . . . . . . . . . . . 

Service Valves

10

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Leak Testing

11

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Evacuation

11

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Start−Up

12

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Refrigerant Charging

12

. . . . . . . . . . . . . . . . . . . . . . . . . . . 

System Operation

14

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Maintenance

15

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Optional Accessories

15

. . . . . . . . . . . . . . . . . . . . . . . . . . 

Homeowner Information

15

. . . . . . . . . . . . . . . . . . . . . . . . 

Thermostat Operation

16

. . . . . . . . . . . . . . . . . . . . . . . . . . 

Start-up & Performance Check List

16

. . . . . . . . . . . . . . 

HSXA16 Outdoor Unit

Two−stage HSXA16 outdoor units use HFC−410A refriger-
ant. This unit must be installed with a matching indoor coil
and line set as outlined in the Lennox Engineering Hand-
book. Elite

®

 Series HSXA16 outdoor units are designed for

use in thermostatic expansion valve (TXV) systems only
and are not for use with other refrigerant flow control de-
vices. The Lennox Engineering Handbook lists a TXV kit
that must be ordered separately.

Shipping & Packing List

1 − Assembled HSXA16 outdoor unit
2 − Grommets (liquid and vapor line)
1 − Bushing (for low voltage wiring)

Check equipment for shipping damage. If you find any
damage, immediately contact the last carrier.

Litho U.S.A.

Summary of Contents for HSXA16 Series

Page 1: ...IONS HSXA16 Series Units CONDENSING UNITS 504 953M 07 06 Supersedes 03 06 Table of Contents HSXA16 Outdoor Unit 1 Shipping Packing List 1 General Information 2 Unit Dimensions 2 Setting The Unit 3 Ele...

Page 2: ...tallation main tenance or repair will expose you to fiberglass wool dust Breathing this may cause lung cancer Fiber glass wool is known to the State of California to cause cancer Fiberglass wool may a...

Page 3: ...lectrical WARNING Electric Shock Hazard Can cause injury or death Unit must be grounded in accordance with national and local codes Line voltage is present at all compo nents when unit is not in opera...

Page 4: ...de wall or where it can be affected by sunlight drafts or vibrations 4 Install low voltage wiring from outdoor to indoor unit and from thermostat to indoor unit NOTE For proper voltages select thermos...

Page 5: ...SXA16 Matched with New Indoor Coil and Line Set If an existing indoor coil that was equipped with an RFCI metering device is being replaced the liquid line must also be replaced prior to the installat...

Page 6: ...eavy nylon wire ties Figure 6 8 feet 8 feet Strap the vapor line to the joist or rafter at 8 ft intervals then strap the liquid line to the vapor line FLOOR JOIST OR ROOF RAFTER Refrigerant Line Sets...

Page 7: ...ends The pipe must remain round do not pinch end of the line 2 Before making line set connections use dry nitrogen to purge the refrigerant piping This will help to prevent oxidation and the introduc...

Page 8: ...system per the in structions below will void the warranty IMPORTANT The Environmental Protection Agency EPA pro hibits the intentional venting of HFC refrigerants during maintenance service repair and...

Page 9: ...d start the recovery machine Open the gauge set valves to allow the recovery machine to pull a vacuum on the ex isting system line set and indoor coil 6 Invert the cylinder of clean HCFC 22 and open i...

Page 10: ...the stem cap Tighten finger tight then torque per table 1 Page 2 To Close Front Seated Service Valves 1 Remove the stem cap with an adjustable wrench 2 Use a service wrench with a hex head extension 3...

Page 11: ...s been add ed fordetection refrigerantrequirements willvarywith line lengths Checkalljoints for leaks Purge drynitro gen and HFC 410A mixture Correct any leaks and re check IMPORTANT Leak detector mus...

Page 12: ...d with a dip tube This system is charged with HFC 410A refrigerant which operates at much higher pressures than HCFC 22 This unit is NOT approved for use with coils which include me tering orifices or...

Page 13: ...d A tem perature pressure chart for HFC 410A refrigerant is provided in table 5 for your convenience Verify ad justed charge using the approach method 4 Use the same digital thermometer you used to ch...

Page 14: ...ervice port and the unit operating stably use a digital ther mometer to record the liquid line temperature 2 At the same time record the liquid line pressure reading 3 Use the temperature pressure cha...

Page 15: ...insufficient cooling the unit should be gauged and refrigerant charge checked Re fer to section on refrigerant charging in this instruction NOTE Outdoor fan motor is prelubricated and sealed No furthe...

Page 16: ...ntinuous in door blower operation regardless of whether the com pressor or furnace is operating This mode is required when constant air circulation or filtering is desired System Switch Set the system...