Page 3
SPECIFICATIONS single phase Cont.
General
D t
Model No.
HPXA12−042
HPXA12−048
HPXA12−060
Data
Nominal Tonnage (kW)
3.5 (12.3)
4 (14.1)
5 (17.6)
Connections
(
t)
Liquid line o.d. − in. (mm)
3/8 (9.5)
3/8 (9.5)
3/8 (9.5)
(sweat)
Vapor line o.d. − in. (mm)
7/8 (22.2)
7/8 (22.2)
1−1/8 (28.6)
Refrigerant (R410A) furnished
9 lb. 2 oz. (4.13 kg)
11 lbs. 5 oz. (5.12 kg)
11 lbs. 3 oz. (5.06 kg)
Outdoor
C il
Diameter − in. (mm) & no. of blades
18 (457) − 4
22 (559) − 4
22 (559) − 4
Coil
Fan
Motor hp (W)
1/3 (249)
1/3 (249)
1/3 (249)
Fan
Cfm (L/s)
2930 (1385)
3890 (1835)
3890 (1835)
Rpm
1100
1085
1085
Watts
310
375
375
Outdoor
C il
Net face area
2
Outer coil
15.21 (1.41)
21.11 (1.96)
21.11 (1.96)
Coil
Net face area
sq. ft. (m
2
)
Inner coil
14.50 (1.35)
20.31 (1.89)
20.31 (1.89)
Tube diameter − in. (mm) & no. of rows
5/16 (8) − 2
5/16 (8) − 2
5/16 (8) − 2
Fins per inch (m)
22 (860)
22 (860)
22 (860)
Shipping Data
lbs. (kg) 1 package
190 (86)
244 (111)
244 (111)
OPTIONAL ACCESSORIES − MUST BE ORDERED EXTRA
Compressor Monitor
(Canada Only)
45F08
45F08
45F08
Hail Guards
17L73
17L74
17L74
Mild Ambient Kit
(LB-101122)
32M08
32M08
32M08
Monitor Kit
(Canada Only)
76F53
76F53
76F53
Outdoor
Th
t t
Thermostat
56A87
56A87
56A87
Thermostat
Kit
Mounting Box − US
31461
31461
31461
Kit
Canada
33A29
33A29
33A29
Plastic
Mounting
Part No. − Catalog Number
MB2-S
(69J06)
MB2-L
(69J07)
MB2-L
(69J07)
Mounting
Base
Net Weight
6 lbs. (3 kg)
15 lbs. (7 kg)
15 lbs. (7 kg)
Refrigerant
Li
S t
30 ft. (9 m) length
L15−65−30
L15−65−30
Field Fabricate
g
Line Set
40 ft. (12 m) length
L15−65−40
L15−65−40
Field Fabricate
50 ft. (15 m) length
L15−65−50
L15−65−50
Field Fabricate
Suction/Vapor Line o.d. − in. (mm)
7/8 (22.2)
7/8 (22.2)
1−1/8 (28.5)
Liquid Line o.d. − in. (mm)
3/8 (9.5)
3/8 (9.5)
3/8 (9.5)
Unit Stand-Off Kit
94J45
94J45
94J45
Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements.
Refrigerant charge is sufficient for 20 ft. (6.1 m) length line set.
NOTE − Extremes of operating range are plus 10% and minus 5% of line voltage
ELECTRICAL DATA
Model No.
HPXA12−018
HPXA12−024
HPXA12−030
HPXA12−036
HPXA12−042
HPXA12−048
HPXA12−060
Line voltage data − 60 hz − 1 phase
208/230v
208/230v
208/230v
208/230v
208/230v
208/230v
208/230v
Recommended maximum fuse or
circuit breaker size (amps)
20
30
35
35
45
50
60
{
Minimum circuit ampacity
14.0
18.0
20.0
20.4
25.9
30.8
36.4
Compressor
Rated load amps
10.3
13.5
15.1
15.4
19.2
23.1
27.6
p
Power factor
.98
.98
.98
.98
.99
.99
.99
Locked rotor amps
51
61
72.5
83
104
134
158
Outdoor Coil
F
M t
Full load amps
1.1
1.1
1.1
1.1
1.9
1.9
1.9
Fan Motor
Locked rotor amps
1.9
1.9
1.9
1.9
4.1
4.1
4.1
Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements.
NOTE Extremes of operating range are plus 10% and minus 5% of line voltage.