www.lennoxhearthproducts.com
126544-01A
32
WIRING DIAGRAM
POWER SUPPL
Y
BO
X
CONTRO
L
MODUL
E
REMOTE CONTRO
L
SPECIFICATIONS
SVFS32PEVF
• Rating (Variable): 20,000/25,000 Btu/Hr
• Type Gas: Propane/LP
• Ignition: Electronic
• Manifold Pressure: 8" W.C.
• Inlet Gas Pressure (in. of water):
Max - 14" W.C., Min* - 11" W.C.
SVFS32NEVF
• Rating (Variable): 20,000/25,000 Btu/Hr
• Type Gas: Natural
• Ignition: Electronic
• Manifold Pressure: 4.5" W.C.
• Inlet Gas Pressure (in. of water):
Max - 10.5" W.C., Min* - 5" W.C.
SVFS36PEVF
• Rating (Variable): 22,000/33,000 Btu/Hr
• Type Gas: Propane/LP
• Ignition: Electronic
• Manifold Pressure: 8" W.C.
• Inlet Gas Pressure (in. of water):
Max - 14" W.C., Min* - 11" W.C.
SVFS36NEVF
• Rating (Variable): 22,000/33,000 Btu/Hr
• Type Gas: Natural
• Ignition: Electronic
• Manifold Pressure: 4.5" W.C.
• Inlet Gas Pressure (in. of water):
Max - 10.5" W.C., Min* - 5" W.C.
*For purpose of input adjustment
f i r e - p a r t s . c o m