5.4002.8501.0
B
5-21
8.
Program the next action in the route:
•
Wall flw L
.
•
Wall flw R
.
•
Straight
.
•
Turn R –>
(see Turn Left or Right on page 5-25).
•
Turn L <–
.
•
Ultrasound L
(see Follow a Wall or Fence on a Certain Distance (Ultrasound) on page 5-26).
•
Charger
.
9.
If the machine has returned to the charging station within 1-3 m., go to the charging station, else
repeat step 6 (see Go to the Charging Station on page 5-27).
10.
Push soft button
EXIT
.
11.
Push soft button
Yes
to save the new route.
Close-up
1.
Test the route (see Test a Route on page 7-4).
2.
Make a backup of the route (see Make a Backup on page 5-31).
5.11.1.1 Follow a Wall (Left or Right)
Try to avoid to move past cows on the left side, they may get hurt due to the opening for
the ultrasonic sensor (see figure 34 on page 5-22).
If the angle between the machine and the wall is more than 30 degrees, you must
program a '
Turn
' action first before you program a '
Follow wall
’
action (see figure 34 on
1.
If the wall is:
•
On the left side, select the menu
Wall flw L
and push
.
•
On the right side, select the menu
Wall flw R
and push
.
2.
Push
to start.
in n o vato rs in ag ric u ltu re
Summary of Contents for DISCOVERY 90 S
Page 2: ...INTENTIONALLY BLANK 5 4002 8501 0 B innovators in agriculture...
Page 6: ...INTENTIONALLY BLANK 5 4002 8501 0 B 6 List of Included Amendments innovators in agriculture...
Page 16: ...INTENTIONALLY BLANK 5 4002 8501 0 B 1 2 Lely Discovery innovators in agriculture...
Page 56: ...INTENTIONALLY BLANK 5 4002 8501 0 B 4 32 Description and Operation innovators in agriculture...
Page 104: ...INTENTIONALLY BLANK 5 4002 8501 0 B 6 12 Maintenance innovators in agriculture...
Page 112: ...INTENTIONALLY BLANK 5 4002 8501 0 B 7 8 Test and Adjustment innovators in agriculture...
Page 134: ...INTENTIONALLY BLANK 5 4002 8501 0 B 9 2 Disposal innovators in agriculture...
Page 137: ......