![LELY DISCOVERY 90 S Operator'S Manual Download Page 129](http://html1.mh-extra.com/html/lely/discovery-90-s/discovery-90-s_operators-manual_1874482129.webp)
5.4002.8501.0
B
8-17
Symptom
Possible cause
Action
Green and Yellow LED together
blink 5 times, followed by a few
seconds rest.
Internal temperature is higher
than 85 degrees C (185 degrees
F).
Remove plug from the mains.
Connect plug and retry after one
hour.
Green and Yellow LED together
blink 7 times, followed by a few
seconds rest.
Current too high (>20 A).
Remove short-circuit, else: Call
your local Lely service provider.