9
Ensure that the machine is only operated in conditions with a maximum humidity of 80% and a maximum ambient tem-
perature of 40°C. Individual components of the machine may no longer function properly if it is used above these limits.
The operator of the machine is responsible for ensuring that the seat height provides the best possible view of the
welding process and prevents posture problems. Ideally, a height-adjustable chair designed for this purpose should
be used.
The machine must be placed on an even sur-
face. Turn all
feet (8)
downward until the ma-
chine rests equally on all
feet
and is suitably
and securely positioned. Use a spirit level to
align the machine. Turn all feet equally when
turning them upward or downward.
Check the machine for damage before commissioning.
Power Supply Connector Plug
The SEAMTEK W-AT is supplied without a connector plug. A suitably trained specialist must connect a plug that
guarantees the specifications of the machine and complies with all statutory requirements specified in the respective
country.
The following specifications regarding the current source and the connector plug must be observed.
Connection Plug
The machine must be connected to a residual-current circuit breaker. Residual-current protection devices prevent
dangerously high ground fault currents and therefore prevent life-threatening electrical accidents.
4.7 Securely Positioning the Machine
8
4.8 Commissioning the Machine
4.8.1 Power Supply
Nominal voltage
V
230 – 240
Frequency Hz
50 / 60
Current A
17
Power cord and extension cable
• The nominal voltage specified on the device must match the supply voltage.
• The cable for the
power connection (18) for the machine
must be freely movable and must not impede users
or third parties during work (tripping hazard).
• The extension cables must be permitted for the utilization site and be marked accordingly. Take into account the
necessary minimum cross-section for extension cables, as required.