43
253
2
Error 253: Can not finish X-/Y-Axis
IN-Movement Backup Source File.
In InManState()
Check if parameter settings are correct or
X-Y-Axis is mechanically blocked
254
2
Error 254: Can not finish X-/Y-Axis
IN-Movement
In InState()
Check if parameter settings are correct or
X-Y-Axis is mechanically blocked, check
Aham right enable setting
255
2
Error 255: Can not get System Time
In PIcTime()
Can not get System Time
256
2
Error 256: Can not get System Time
In PIcTime()
Can not set System Time
257
2
Error 257: LvWedge Current / Current too
low
In LvWedge ()
Error occured in Current Measurement.
Check connection between Shunt and PLC
258
2
Error 258: Can not open Backup Source File. Machine Settings File on PLC (SPS) corrup-
ted. Do recover your Data from your Memory
Stick.
259
2
Error 259: Can not open Backup Destination
File.
Missing Memory Stick.
260
2
Error 260: Can not read Backup Source File.
Machine Settings File on PLC (SPS) corrup-
ted. Do recover your Data from your Memory.
261
2
Error 261: Can not write Backup Destination
File.
Missing Memory Stick.
262
2
Error 262: Can not close Backup Destination
File.
Missing Memory Stick.
263
2
Error 263: Can not close Backup Source File. Machine Settings File on PLC (SPS) corrup-
ted. Do recover your Data from your Memory.
264
2
Error 264: Can not open Recovery Source
File.
Machine Settings File on Memory Stick cor-
rupted. Do backup your Data from PLC (SPS)
to Memory Stick.
265
2
Error 265: Can not open Recovery Destina-
tion File.
Machine Settings File on PLC (SPS) corrup-
ted.
266
2
Error 266: Can not read Recovery Source
File.
Machine Settings File on Memory Stick cor-
rupted. Do backup your Data from PLC (SPS)
to Memory Stick.
267
2
Error 267: Can not write Recovery
Destination File.
Machine Settings File on PLC (SPS) corrup-
ted.
268
2
Error 268: Can not close Recovery
Destination File.
Machine Settings File on PLC (SPS) corrup-
ted.
269
2
Error 269: Can not close Recovery Source
File.
Machine Settings File on Memory Stick cor-
rupted. Do backup your Data from PLC (SPS)
to Memory Stick.
278
2
Error 278: PWR_SUP_LVW / current too low
In LvWedge()
Power Supply lacks in weld current. Power
Supply needs maintenance or low setting in
Energy parameter
279
2
Error 279: LvWedge Voltage / Voltage too
low
In LvWedge()
Error occured in Voltage Measurement.
Check connection between Wedge and Wed-
ge holder. Wedge is broken or damaged.
290
2
Error 290: Supervision, EL6080 NOVRAM,
Load: FB Read/Write busy for t>200ms
Can not read Meter Hours during Startup of
Supervision Extension.
Shutdown SEAMTEK W-AT Machine and
restart.
291
2
Error 291: Supervision, EL6080 NOVRAM,
fbWrite.bError
fbWrite Error in INIT State of EL6080.
Shutdown SEAMTEK W-AT Machine and
restart.