background image

3

Leica EG F

The information, numerical data, notes and value judgments contained in this Instructions for Use 
represent the current state of scientific knowledge and state-of-the-art technology as we understand  
it following thorough investigation in this field. 

We are under no obligation to update the present Instructions for Use periodically and on an ongoing 
basis according to the latest technical developments, nor to provide our customers with additional 
copies, updates etc. of this Instructions for Use.

To the extent permitted in accordance with the national legal system as applicable in each individual 
case, we shall not be held liable for erroneous statements, drawings, technical illustrations etc. 
contained in this Instructions for Use. In particular, no liability whatsoever is accepted for any financial 
loss or consequential damage caused by or related to compliance with statements or other information 
in this Instructions for Use.

Statements, drawings, illustrations and other information regarding the contents or technical details of 
the present Instructions for Use are not to be considered warranted characteristics of our products.

These are determined only by the contract provisions agreed between ourselves and our customers.

Leica reserves the right to change technical specifications as well as manufacturing processes without 
prior notice. Only in this way is it possible to continuously improve the technology and manufacturing 
techniques used in our products.

This document is protected under copyright laws. All copyrights to this documentation are held by 
Leica Biosystems Nussloch GmbH.

Any reproduction of text and illustrations (or of any parts thereof) by means of print, photocopy, 
microfiche, web cam or other methods – including any electronic systems and media – requires express 
prior permission in writing by Leica Biosystems Nussloch GmbH.

For the instrument serial number and year of manufacture, please refer to the nameplate on the back of 
the instrument.

Note

Leica Biosystems Nussloch GmbH 
Heidelberger Str. 17 - 19 
D-69226 Nussloch 
Germany 
Tel.: 

+49 - (0) 6224 - 143 0 

Fax: 

+49 - (0) 6224 - 143 268 

Web: 

www.LeicaBiosystems.com

Assembly contracted to Leica Microsystems Ltd. Shanghai

Summary of Contents for EG F

Page 1: ...F Heatable forceps Instructions for Use English Order No 14 0388 83101 Revision H Always keep this manual with the instrument Read carefully before working with the instrument Version 1 5 Revision H...

Page 2: ......

Page 3: ...tion regarding the contents or technical details of the present Instructions for Use are not to be considered warranted characteristics of our products These are determined only by the contract provis...

Page 4: ...ctions 8 2 2 Warnings 9 3 Installation 10 3 1 Unpacking instructions 10 3 2 Standard delivery 11 3 3 Setting up the instrument Site requirements 12 3 4 Electrical connection 12 4 Instrument Characteri...

Page 5: ...contact with these surfaces they may cause burns Symbol Title of the symbol Alternating current Symbol Title of the symbol Manufacturer Description Indicates the manufacturer of the medical product Sy...

Page 6: ...d must be handled with care Symbol Title of the symbol Keep dry Description The package must be kept in a dry environment Symbol Title of the symbol Regulatory Compliance Mark RCM Description The Regu...

Page 7: ...of the instrument other than its designated use is considered improper Note These Instructions for Use must be appropriately supplemented as required by the existing regulations on accident preventio...

Page 8: ...ulations on accident prevention and environmental safety in the operator s country Warning The protective devices located on the instrument and the accessories must not be removed or modified Only ser...

Page 9: ...by authorized service technicians only Switch the instrument off and unplug it before each cleaning Do not use any solvent containing acetone or xylene for cleaning When using cleaners please comply w...

Page 10: ...his on the shipping documents if necessary Fig 1 Fig 2 Fig 3 1 Carefully cut through the adhesive tape at the indicated locations Fig 1 2 Remove the provided bag with documents including the User Manu...

Page 11: ...n it to the opposite side insert screws in corresponding holes on opposite side 3 2 Standard delivery Qty Part No 1 Base unit 14 0388 35824 1 Control unit with voltage selector switch 100 120 220 240V...

Page 12: ...n condensing Room temperature consistently between 18 C and 40 C Elevation up to a max 2000m above sea level The instrument is designed for indoor use only Avoid vibrations direct sunlight and heavy v...

Page 13: ...crewdriver in the slot Fig 5 4 and move the setting to the desired value Fig 5 4 Connecting to mains Warning Before connecting the instrument to the mains ensure that the voltage selector switch is se...

Page 14: ...ket Connect the plug of the power cord to the connecting socket Fig 6 3 on the rear of the control unit Connect the plug of the power cord to the power socket Replacing fuses Warning Switch the instru...

Page 15: ...rview instrument components functions Control instrument front view Fig 7 1 3 2 4 Control unit rear view Fig 8 7 5 6 1 Control panel 5 Mains switch 2 Heatable forceps tip width 1mm with cable 6 Socket...

Page 16: ...If the preselected operating temperature is reached this indicator lights permanently thereby signaling its readiness Temperature display Two options are available for selecting the temperature displa...

Page 17: ...ing temperature range 18 C to 40 C Adjustable temperature range 55 C to 70 C Storage temperature range 5 C to 50 C IEC 1010 classification Protection class 1 Pollution degree 2 Overvoltage category II...

Page 18: ...the exterior surfaces use a mild and pH neutral commercial household cleaner You may NOT use Alcohol cleaning materials containing alcohol glass cleaner abrasives or solvents containing acetone or xy...

Page 19: ...al contract concluded being regarded as binding only the warranty conditions of your local Leica sales unit or of the company from which you acquired the product Technical service information If you r...

Page 20: ...w LeicaBiosystems com within the product menu This template has to be used for gathering all required data When returning a product a copy of the filled and signed confirmation has to be enclosed or p...

Page 21: ......

Page 22: ...w LeicaBiosystems com Version 1 5 Revision H 10 2018 Leica Biosystems Nussloch GmbH Heidelberger Str 17 19 D 69226 Nussloch Germany Tel 49 0 6224 143 0 Fax 49 0 6224 143 268 Web www LeicaBiosystems co...