26
Use of outriggers
The outriggers must be deployed, and the chassis of the access platform must be levelled
before any boom operations. The chassis can be levelled by either using automatic levelling
function or controlling individual outriggers manually. The maximum allowed levelling
inaccuracy is 1,0°.
Make sure that the ground under every outrigger is solid
–
put extra plates on the ground if
necessary.
Outriggers can only be operated when the booms are in transport position!
Booms must not be operated without properly deployed outriggers!
Automatic levelling
1.
Switch on the machine and select platform controls
2.
Turn on the combustion engine or the electric motor
3.
Push the automatic levelling button (Figure 7 (18
)). The button doesn’t need to be held
down.
4.
The access platform will deploy all outriggers and level the chassis automatically.
5.
While the levelling is in progress the green light of the automatic levelling will blink.
6.
If the levelling procedure must be stopped, press the levelling button again.
7.
Automatic levelling will end if user leaves the basket while levelling is running.
8.
When the chassis is levelled the green light of the automatic levelling (Figure 7 (19)) will stay
on continuously.
9.
Booms can be operated any time when the green “
levelling
ok” light is lit
10.
Make sure wheels/tracks are not on ground after levelling is done. Push automatic levelling
again if necessary, to raise machine higher from ground.
Manual levelling
1.
Switch on the machine and select platform controls
2.
Start the combustion engine or the electric motor
3.
Use the outrigger levers (Figure 7 (17)) to deploy outriggers
4.
First: lower two back outriggers so they touch the ground
5.
Second: lower the two front outriggers so they touch the ground as well
6.
Lower the outriggers low enough: minimum chassis lift height is high enough, so the wheels
or tracks visibly lift of the ground
7.
Once all outriggers touch the ground, use the outrigger levers to level the machine. The
levelling is easiest when lowering the outriggers in pairs (for example both left side
outriggers together or both front outriggers together)
8.
Green light above the automatic levelling button will blink when all outriggers have ground
contact but chassis is not levelled.
9.
When the chassis is levelled the green light above the automatic levelling button will be lit
up continuously.
Summary of Contents for 135 NEO
Page 1: ...Operator and Service manual Version 7 2020 July 2020 ...
Page 9: ...9 Main dimensions Figure 2 135 NEO Main dimensions side Figure 3 135 NEO main dimensions rear ...
Page 10: ...10 Reach diagram and support dimensions Figure 4 Reach diagram Figure 5 Support dimensions ...
Page 59: ...59 Figure 37 Load control of the platform Figure 38 Boom position monitoring ...
Page 60: ...60 Figure 39 Platform levelling monitoring Figure 40 Outrigger monitoring ...
Page 61: ...61 Figure 41 Transport position monitoring Figure 42 Prevention of drive function ...
Page 64: ...64 Figure 47 Platform load monitoring override Figure 48 Override of Safety Functions ...