background image

14

CABLEADO

120 – 277 VAC (1

φ

), 50/60 Hz

20A Ballast/ELV/MLV/Tungsten/LED

16A E-Ballast/CFL

1HP @ 120/240VAC

20A 120VAC Plug Load – Receptacle

Class 2 Output

24 VDC, 225 mA

BZ-200 Power Pack

UL 2043 Plenum Rated

16094r1

Appliance

Control

LISTED

88T9

Control

Common

+24VDC

Red

White

Neut.

Power Pack

Re

d

Blac

k

Blue

Switch

Lighting

Load

Black

Any 3-Wire

24VDC

Sensor 

Hot

Red

Ground

Green

Class 2

wiring only

+VCC (Rojo)

Común (Negro)

Control (Azul)

(Gris)

(Violeta)

Linea (Negro)

Tierra

(Verde)

Neutro

(Blanco)

www.legrand.us  •  800.879.8585

Controlador

No-Atenuable

120 – 277 VAC (1

φ

), 50/60 Hz

20A Ballast/ELV/MLV/Tungsten/LED

16A E-Ballast/CFL

1HP @ 120/240VAC

20A 120VAC Plug Load – Receptacle

Class 2 Output

24 VDC, 225 mA

BZ-200 Power Pack

UL 2043 Plenum Rated

16094r1

Appliance

Control

LISTED

88T9

Control

Common

+24VDC

Red

White

Neut.

Power Pack

Re

d

Blac

k

Blue

Switch

Lighting

Load

Black

Any 3-Wire

24VDC

Sensor 

Hot

Red

Ground

Green

Class 2

wiring only

+VCC (Rojo)

Común (Negro)

Control (Azul)

Neutro

(Blanco)

Linea (Negro)

Tierra

(Verde)

Atenuar– (Gris)

(Violeta)

www.legrand.us  •  800.879.8585

Controlador

Atenuable

Salida de +VCC (Rojo)

Común

/Tierra (Negro)

Neutro (Blanco)

Linea (Negro)

Tierra (Verde)

Atenuar– (Gris)

(Violeta)

(Azul)

Controlador 

Atenuado-a-Apagado

Cableado con 

un suministro 

de alimentación 

externo de CC

NAVEGACIÓN

La navegación se logra seleccionando cualquiera de los 

parámetros deseados. Los ajustes se pueden cambiar a 

través del número de entradas o deslizadores.

NOTA: 

Al cambiar los 

valores de los 

parámetros en 

el FSP-301B, es 

necesario esperar 

unos 3 minutos 

antes de que los 

nuevos parámetros 

se guarden en la 

memoria.

CONFIGURACIÓN FSP-301B CON EL APLICACIÓN 

DE CONFIGURACIÓN DEL SENSOR

La aplicación de configuración del sensor está 

disponible para dispositivos iOS

®

 y Android

®

Busque “Wattstopper Sensor Config” en su 

dispositivo para descargar.

NOTA: 

Los rangos de comunicación Bluetooth 

pueden variar según el dispositivo, así como el operador 

de telefonía móvil. Wattstopper recomienda dispositivos 

con Bluetooth 5.0. El iPhone 8 y Samsung Galaxy S8 

y dispositivos posteriores, son recomendados para un 

rendimiento óptimo.

La herramienta de configuración del 

sensor es una aplicación móvil para 

cambiar los valores predeterminados y 

las pruebas del FSP-301. Proporciona 

acceso inalámbrico a los sensores 

FSP-301B para los cambios de 

parámetros y las pruebas. Dentro de 

una determinada altura de montaje 

del sensor, la aplicación Sensor 

Configuration permite la modificación 

del sistema sin necesidad de escaleras 

ni herramientas. 

Si no se toman 

medidas de configuración, el sensor 

utilizará sus valores de parámetros 

predeterminados.

La pantalla de la aplicación Sensor 

Configuration muestra menús e 

indicaciones para guiarle a través de cada proceso. La aplicación 

para móviles proporciona una forma sencilla de navegar por los 

campos de personalización.
La aplicación Sensor Configuration permite la comunicación 

bidireccional entre la FSP-301B y la aplicación. Pantallas de menú 

simples le permiten ver el estado actual del sensor y realizar 

cambios. Puede cambiar los parámetros del sensor FSP-301B 

tales como modo alto / bajo, sensibilidad, tiempo de retardo, corte 

y más. Con la aplicación Sensor Configuration también puede 

establecer y almacenar perfiles de parámetros FSP-301B y habilitar 

la atenuación continua.
La aplicación móvil Sensor Configuration tiene la capacidad de 

detectar múltiples sensores basados en la intensidad o la distancia 

de la señal. Cada vez que la herramienta establece comunicación 

con el FSP-301, la carga controlada parpadeará, proporcionando 

una indicación visual de qué FSP-301B está configurando.

Summary of Contents for Wattstopper FSP-301B

Page 1: ...usly raise or lower the dimming level of the lighting loads based on the ambient light and desired light level setting The FSP 301B operates at 12 32 VDC It is designed to be installed in indoor and o...

Page 2: ...face of the fixture If needed add the nut between the sensor body and the rubber gasket to ensure a secure fit Install the nipple nut securely against the fixture to a torque of 25 30 in lbs to ensure...

Page 3: ...TE Bluetooth communication ranges can vary depending on the device as well as mobile carrier Wattstopper recommends devices with Bluetooth 5 0 Iphone 8 and Samsung Galaxy S8 and later devices are reco...

Page 4: ...setpoint needs to be adjusted If set for minimum more than 1 fc at the sensor of ambient light will cause the lights to be held OFF See the new settings section for instructions If lights still do not...

Page 5: ...digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment...

Page 6: ...e fixation suspendu pour l installation sur un poteau ou sur un luminaire Le d tecteur utilise la technologie de d tection par infrarouge passif IRP qui r agit aux changements dans l nergie infrarouge...

Page 7: ...en caoutchouc au raccord et installez le d tecteur face vers le bas Assurez vous que le joint en caoutchouc touche la surface du luminaire Si n cessaire ajoutez l crou entre le corps du d tecteur et...

Page 8: ...ppareils iOS et Android Rechercher Wattstopper Sensor Config sur votre appareil pour le t l charger REMARQUE La qualit du signal et la distance de communication Bluetooth peuvent varier en fonction de...

Page 9: ...haut V rifiez toutes les connexions et la charge et assurez vous que les fils de terre sont bien fix s Assurez vous que le d tecteur n est pas obstru V rifiez le param tre du niveau de luminosit pour...

Page 10: ...ous tension il se produit un pr chauffage de 50 secondes La charge s teindra apr s le temps de pr chauffage si aucun mouvement n est d tect RENSEIGNEMENTS POUR COMMANDES Num ro de Catalogue Descriptio...

Page 11: ...tilisateur doivent tre maintenu en tout temps Tout changement ou modification non express ment approuv par The Watt Stopper Inc pourrait annuler le droit de l utilisateur utiliser l quipement D CLARAT...

Page 12: ...boquilla detr s El FSP 301B D posee una boquilla de montaje de ca da para montar en un polo o en la luminaria Los sensores usan tecnolog a de detecci n de infrarrojo pasivo PIR que reacciona a los ca...

Page 13: ...de 22 mm 0 875 de di metro a trav s del polo 3 Agregue la empaque de goma a la boquilla e instale el sensor boca abajo Aseg rese de que la empaque de goma toque la superficie de la luminaria Si es ne...

Page 14: ...el sensor est disponible para dispositivos iOS y Android Busque Wattstopper Sensor Config en su dispositivo para descargar NOTA Los rangos de comunicaci n Bluetooth pueden variar seg n el dispositivo...

Page 15: ...s luces no pasan al Modo alto Controle todas las conexiones de cables y verifique la carga y que los cables de regulaci n est n bien ajustados Aseg rese de que el sensor no est bloqueado Controle el p...

Page 16: ...entamiento La carga se apagar despu s del tiempo de calentamiento si no se detecta movimiento INFORMACI N PARA HACER PEDIDOS N de cat logo Descripci n FSP 301B Fase simple doble universal Atenuaci n C...

Page 17: ...osici n a radiofrecuencia RF la FCC e IC para dispositivos m viles Este dispositivo solo est autorizado para su uso en una aplicaci n m vil Al menos 20 cm de distancia de separaci n entre este disposi...

Page 18: ...18...

Page 19: ...19...

Page 20: ...on ou la performance de ce produit ou tout autre dommage indirect li la perte de propri t de revenus ou de profits ou aux co ts d enl vement d installation ou de r installation WattStopper garantiza q...

Reviews: