46
TECHNICAL CHARACTERISTICS
Ambient operating conditions
Temperature of use
-30 - +70°C
Storage temperature
-30 - +80°C
Relative humidity
< 80% (IEC/EN 60068-2-78)
Maximum environmental pollution
Degree 2
Overvoltage category
3
Measurement category
III
Climate seuence
Z/ABDM (IEC/EN 60068-2-61)
Shock resistance
15g (IEC/EN 60068-2-27)
Vibration resistance
0.7g (IEC/EN 60068-2-6)
Connections
Terminal types
Removable screw-type
Wire cross-section area (min. and max.)
0,2-2,5 mm (24
÷
12 AWG)
UL use data
Wire cross-section area (min. and max.)
0,75-2.5 mm² (18-12 AWG)
Tightening torue
0,56 Nm (5 Lbin)
Housing
Installation
Flush mount
Material
Polycarbonate
Frontal degree of protection
IP40 on front,
IP65 with optional gasket
IP20 on terminals
Weight
680g
Certifications and compliance
Certifications obtained
EAC
Comply with standards
IEC/EN 61010-1, IEC/EN 61010-2-030,
IEC/EN 61000-6-2, IEC/ EN 61000-6-4,
4. Technical characteristics