8. With the radiant box placed in the opening, mark out four of the eight fixing holes. Remove the box and
carefully drill and fit rawl plugs.
9. Temporarily fix the flue spigot to the rear of the
radiant box with the the four self tapping screws
provided. Offer the radiant box with the spigot
attached into the fireplace opening (carefully tuck
the cables behind the box into the cavity). The
spigot should protrude through the outer hole in
the brickwork. Screw the radiant box to the back
panel.
10. Remove the painted fan box cover (four
screws) and remove the actual fan unit from the
wall plate (four screws). Place the fan unit and
painted cover carefully to one side (avoiding any
moisture, rain etc).
11. From the outside, position the wall plate into
the cut out of the brickwork and over the
protruding spigot ensuring that the wall plate
flanges are flat against the brickwork. Mark the flue spigot so that it would be just below ‘flush’ with the face of
the wall plate (on final fix the spigot should not touch any part of the fan unit as this can cause a vibration noise).
Remove the radiant box and cut the spigot to length.
12. Having cut the spigot to length, the radiant box should be offered up to the fireplace opening for the final fix.
Before fixing, the power cable should be fed round the back of the fireplace to a wall mounted power source.
This can be a three pin plug fused 3amp or by a fixed connection to a 3amp, all pole switched fused spur. The
spur must have a contact separation of at least 3mm. The five core cable with the 6 way plug should be
temporarily fed through the spigot hole. The radiant box can now be screwed securely to the back panel.
INSTALLING THE FAN UNIT
Warning - This Appliance MUST Be Earthed
1. Take the wall plate and place into the outside hole and over the cut to length spigot making sure that the inner
and outer spigots line up with each other centrally.
Make sure that the cable entry hole is in the top right hand corner (as the fan will only fit one way round)
INSTALLATION PROCEDURE
CONTINUED
8
Fig. 6
Fig. 7
Fixing
Holes
Fixing
Holes
Fixing Holes
Face of Wall Plate
Flue Spigot
Cut Line