User Manual PXA125
Specifications A-94
Advance
Automatic, triggered, gated or software command
Marker
Output and Level
Same as SYNC output.
Position
Programmable for selected frequency
OPERATING MODES
Normal
Continuous waveform is generated
Triggered
Each input cycle generates a single output cycle.
Gated
External signal enables generator. First output cycle
synchronous with the active slope of the triggering signal. Last cycle of output waveform always com-
pleted
External Burst Preset number of up to 128K cycles stimulated by an internal, or external
trigger. This mode is not available in Sequence mode.