Logic Pattern Trigger Setup
The Logic Pattern Trigger dialog, with detail on some of the setup conditions, is shown in the
following images:
Select a value for any of the digital lines by touching the existing value (using either your finger or
a mouse), opening the pop-up menu with a list of choices, and then selecting one of the choices.
Alternatively, you can set a hex value by byte (or view what the resulting hex value conversion).
Touch the arrow buttons to scroll to the next group of eight digital lines. Note that you may set a
digital line to any value in the Logic trigger setup even if it is not defined as part of a Digital group.
PLEASE NOTE THE FOLLOWING:
You may set a digital line to any value in the Logic trigger setup even if it is not defined as part of a Digital group.
You can set multiple digital lines to different edge conditions. However, the edge conditions are always grouped in an
OR trigger condition.
Logic Pattern
Trigger can be
configured to
use up to 4
analog channels
and 36 digital
channels