2. SPECIFICATIONS
20
Time Accuracy
±0.5 %
Cursor Measurement
Composition
Horizontal Cursors
2 (REF and DELTA)
Vertical Cursors
2 (REF and DELTA)
Amplitude Measurement
mV, %, R%, DEC, HEX
Time Measurement
Second display
Frequency Display
Computes and displays the frequency with the length of
one period set to the time between two cursors
Scale
Type
%, V, decimal, hexadecimal
Color
7 colors to choose from
*1
2H display is not possible when the input signal is 3G (DL), 3G (QL), or HD (QL).
*2
2V display is not possible when the input signal is progressive.
2.3.15
SDI Vector Waveform Display
Color
7 colors to choose from
Blanking Interval
Masked
Pseudo-Composite Display
Artificially converts component signals into composite
signals and displays the result
Line Select
Displays the selected line
Gain
×1, ×5, IQ-MAG
Variable Gain
×0.2 to ×2.0
Amplitude Accuracy
±0.5 %
Scale
Type
ITU-R BT.601, ITU-R BT.709, AUTO
Setting the Color Bar Saturation
75 %, 100 %
IQ Axis
Show or hide
Color
7 colors to choose from
Vector Marker Display
Displays a marker and numeric value at the specified
location on the vector display
Number of Markers
1
Numeric Display
Displays the marker position numerically
Cb
Displays the CB position as a percentage
Cr
Displays the CR position as a percentage
deg
Displays the hue in degrees.
d
Displays the distance from the center as a percentage
USO
RESTRITO
Summary of Contents for LV 5490
Page 2: ...TABLE OF CONTENTS USO RESTRITO...
Page 3: ...USO RESTRITO...
Page 4: ...USO RESTRITO...
Page 5: ...USO RESTRITO...
Page 132: ...10 MENU TREE 123 10 2 INPUT Menu USO RESTRITO...
Page 133: ...10 MENU TREE 124 10 3 SYS Menu USO RESTRITO...
Page 134: ...10 MENU TREE 125 10 4 CAP Menu USO RESTRITO...
Page 135: ...10 MENU TREE 126 10 5 PSET Menu USO RESTRITO...
Page 139: ...USO RESTRITO...