HINGE (PULL) SIDE
MOUNTING
MAXIMUM OPENING
Templating allows 120° with
standard arm, limited to
110° when optional bumper is
installed.
Hold-open points at 85°, 90°, 95°,
100°, 105° , or 110°, depending on
the clip location in track.
Please note that many track style door
closers are capable of allowing 180°
of door swing. Be aware that the
majority of track style closers are at
their weakest closing force in the
180 – 130° range. Consult factory for
applications where exterior or
large/heavy door must swing 180°.
LCN
4040T SERIES
Butt Hinges
should not exceed 5” (127 mm) in width.
Auxiliary Stop
is recommended at hold-open point or where a door
cannot swing 120°. Optional track bumper assembly assists backcheck in
cushioning the opening swing of the door. It is not intended to replace an
auxiliary stop.
Reveal
should not exceed 1/8” (3 mm) for standard arm.
Top Rail
less than 3 3/4” (95 mm) requires PLATE, 4040T-18. Plate
requires 1 13/16” (44 mm) minimum.
Head Frame
requires 1 1/4” (32 mm) minimum.
Clearance
of 2 1/4” (57 mm) behind door required for 90° installation.
Options
Standard track with bumper,
hold-open track, hold-open
track with bumper.
Metal cover.
ST required for double egress
applications. Consult factory
Special Templates
Customized installation templates
or products may be available to
solve unusual applications. Contact
LCN for assistance.