PCSS-F Additions Technical Manual
LS-CS-M-023
Page 4-22
Original Language Version:
1.02
Released:
03/12/2013
4.2.2.7
Enable Monitors
This option monitors enables and monitors the outputs required to drive and stop the press.
Two enable outputs are required to allow movement of the pressing beam as shown in
Enable 1 Monitor
X20
X21
X22
X23
X24
FIO04
–
CN7
1
2
3
4
5
X25
6
X26
7
X27
8
X28
9
X29
X30
X31
10
11
12
P20
24VDC
0VDC
13
14
15
Enable 2 Monitor
X38
X39
X40
X41
Y08
FIO04
–
CN10
1
2
3
4
5
Y09
6
24VDC
7
0VDC
8
0VDC
9
Enable 1
Enable 2
Figure 4-18: Option 7 Enable Monitors (CN10/7 - FIO04 Connections)
4.2.2.8
On Switch Monitor
On Switch
X10
X11
X12
X13
P10
FIO04
–
CN5
1
2
3
4
5
P11
6
P12
7
24VDC
8
Figure 4-19: Option 7 ON Switch (CN5 - FIO04 Connections)
The ON switch, as illustrated in
for the FIO04, is used to control the emergency
stop circuit of the press brake. This ensures that if the ON switch is in the deactivated position
any associated press brake operation is disabled and any control or movement of the pressing
beam can be prevented. The ON switch illustrated in
position.