PCSS-F Additions Technical Manual
LS-CS-M-023
Page 4-26
Original Language Version:
1.02
Released:
03/12/2013
X03
X04
X05
X06
X07
FIO04
–
CN4
1
2
3
4
5
X08
6
X09
7
Y06
8
0VDC
9
Y07
0VDC
P03
10
11
12
P04
13
24VDC
14
Station 1 Indicator
Station 2 Indicator
X38
X39
X40
X41
Y08
FIO04
–
CN10
1
2
3
4
5
Y09
6
24VDC
7
0VDC
8
0VDC
9
Station 4 Indicator
Station 3 Indicator
Figure 4-24: Error Reset Option 6 (CN4
-
FIO04 Output Connections)
This error reset option is intended for use with down switch options allowing four operator
stations. The error reset function selects the active station for single operator configuration
or station 1 in the dual operator configuration.
4.3.3.1
Option Selection
To select error reset option 6 during the PCSS configuration, set the initial value for the error
reset option selection variable to
6
. This will ensure that this option is initialised with all required
inputs activated when the PCSS software is started.