10. INSPECTIONS AND MAINTENANCE
10.1. Weekly and daily cleaning
Daily
Body: clean the outer panels and steam wands with a
cloth dampened in lukewarm water. Do not use abrasive
or alcohol based detergents which may scratch or da-
mage the mechanical structure of the body.
Grid and drip tray: carefully clean in order to prevent
mould growth inside.
Used capsule drawer: carefully clean in order to prevent
mould growth inside.
Weekly
Water tank: empty and wash the internal part of the tank
with lukewarm water, in order to prevent limescale.
10.2. Descaling
Warning
It is recommended the machine be descaled at least
once a year . According to the hardness of the water,
it may be necessary to carry out descaling more fre-
quently.
A special kit, composed of a dummy capsule (A) and a
discharge hose (B), is necessary to carry out the de-
scaling cycle.
Note
The kit can be ordered in the interactive spare parts
area of the site: ts.lavazza.it.
Descaling operations
- Switch the machine off by means of the on/off switch.
- Empty the tank and used capsule drawer.
- Fill the tank with water and descaling product.
Note
For correct quantity of the descaling product, refer
to the instructions reported on the product.
- Lift the loading handle and insert the dummy capsule
(A).
Attention
The handle should be closed in such a way as to rest
on the dummy capsule grip (A) as shown in the fi-
gure.
- Connect the discharge hose (B) to the machine di-
spensing spout and put the other end inside a contai-
ner to collect water.
- Turn the machine on with the on/off switch by keeping
the button (
3
) pressed for 7 seconds.
Maintenance manual for technical assistance
Manual code 10081945 / Rel. 0.00 / February 2014
20
A
B
A
3