Maintenance manual for technical assistance
11
Manual code 10081945 / Rel. 0.00 / February 2014
7.6. Disassembling the boiler unit
Attention
Carry out these operations with
the boiler cooled. DANGER OF
BURNING.
Disconnect the electrical and hy-
draulic connections shown in the fi-
gure, loosen screws (1) and (2) to
disconnect the temperature probe
(3) and thermal fuses (4).
Disconnect the four screws (5) and
remove the boiler (6).
7.7. Disassembling thermal safety and temperature detection systems
Disconnect the connection shown in
the figure.
Loosen the screw (1).
Turn the clamp (2).
Remove the thermal fuses (3) from
the protective pipes (4).
Disconnect the electrical connec-
tions (5).
Attention
When thermal fuses are replaced after triggering the temperature probe must also be replaced.
2
1
3
4
4
5
5
5
5
A
1
2
3
4
5
A
6