Operation
16
INSTALLATION, MAINTENANCE AND USER' MANUAL
549263_D_PUB_DATE_7_JUL_2014.DOC
N°
Failure message
Failure
Action
Fault occurrence
E32
Verify Par
Verification fault
frequency inverter
parameters
Don’t start
At loading parameters
E35
Wrong Softw
Wrong software
version
Don’t start
New software version
E36
Imbalance
Unbalance detection
system activated.
Reduction of spinning
sequence revolutions.
For Info only.
Spinning sequence
E37
No Drain Spr
Drain failure at the
Spray Sequence
Full stop + tumble
Spray Sequence
E38
No Recycle
The Tank with recycle
water is empty
Warning at the End.
Front soap dispenser
Mach. only
Wash step
E39
Out of Soap
The Soap Supplies
are running Out of
Soap
For Info only
Wash step
E41
Service Due
Service Due Warning
For Info only
Open door = reset
End cycle
E42
Connection
No Network
Connection
For Info only
Data Transfer Networking
E43
Voltage Par
Wrong Voltage
Range Selection
Make correct selection
Configuration menu
E44
Model Type
Incorrect selection
of machine type
Make correct selection
Configuration menu
E80
SoapTimeOut
Incorrect signal for
liquid detergent
dispensing
Full stop + tumble.
Whole cycle
E81
No Reheat
Heating Failure
Full stop + tumble.
Wash Step
(Traceability only)
E82
No Refill
Refill failure
Full stop + request for
Continue
Wash Step
(Traceability only)
E83
Power Interruption
No successful wash
cycle termination
Info that the wash cycle
has to be repeated.
Abnormal Cycle Termination
(Traceability only)
E85
RTC Reset Bat
Real Time Clock, No
Battery or battery low
power
For Info only.
End cycle
(Traceability only)
E100
Weigh No Comm
Communication fault
weighing system
Full Stop Tumble
(machines with weighing
system only)
E101
Weigh Low
Weight machine is too
low
Don't Start
(machines with weighing
system only)
E102
Weigh High
Weight machine is
too high
Don't Start
(machines with weighing
system only)
E103
Weigh Balance
Weight is not balanced
over 4 load cell's.
Don't Start
(machines with weighing
system only)
E104
Weigh Overload
Weight on individual
load cell exceeds max.
Full Stop Tumble
(machines with weighing
system only)
E300-
E353
Mits Err
Specific Mitsubishi
Inverter Alarm
Full stop + safety time
Whole cycle
E500-
E525
Memory Err
Memory Error
Full stop + safety time
Any time