Technical data
28
INSTALLATION, MAINTENANCE AND USER' MANUAL
549263_D_PUB_DATE_7_JUL_2014.DOC
Rigid-mount machines 14 kg / 30 lb
not
standard
according
to the request
Phase
Voltage
[V]
Frequency
[Hz]
Total power
[kW]
Fuse
[A]
Motor output
[kW]
Heating
[kW]
Ingress
protection
IP
1 120 60 0.85 20 0.75 0 43
1 200-240
50/60 0.85
16
0.75
0
43
1
200-240
50/60
5.5
32
0.75
4.6
43
1
200-240
50/60
6.8
32
0.75
6
43
1
200-240
50/60
9.8
50
0.75
9
43
3
200-240
50/60
0.85
16
0.75
0
43
3
200-240
50/60
6.8
25
0.75
6
43
3 200-240
50/60 9.8
32
0.75
9
43
3 200-240
50/60 12.8
40
0.75
12
43
3
200-240
50/60
14.6
50
0.75
13.8
43
3
380-415 + N
50/60
0.85
16
0.75
0
43
3
380-415 + N
50/60
6.8
16
0.75
6
43
3
380-415 + N
50/60
9.8
20
0.75
9
43
3
380-415 + N
50/60
12.8
25
0.75
12
43
3
380-415 + N
50/60
14.6
32
0.75
13.8
43
3 380-415
50/60 0.85
10
0.75
0
43
3 440-480
50/60 0.85
10
0.75
0
43
3
380-415
50/60
6.8
16
0.75
6
43
3
440-480
50/60
7.8
16
0.75
7
43
3 380-415
50/60 9.8
20
0.75
9
43
3 440-480
50/60 9.8
16
0.75
9
43
3 380-415
50/60 12.8
25
0.75
12
43
3 440-480
50/60 12.8
25
0.75
12
43
3
380-415
50/60
14.6
32
0.75
13.8
43
3
440-480
50/60
14.6
32
0.75
13.8
43
Table 15 – Rigid-mount machines 14 kg / 30 lb
Rigid-mount machines 18 kg / 40 lb – normal spin
not standard
Phase
Voltage
[V]
Frequency
[Hz]
Total power
[kW]
Fuse
[A]
Motor output
[kW]
Heating
[kW]
Ingress
protection
IP
1 200-240
50/60 0.85
10
0.75
0
43
3
200-240
50/60
0.85
10
0.75
0
43
3 200-240
50/60 12.7
40
0.75
12
43
3 200-240
50/60 18.7
63
0.75
18
43
3
380-415 + N
50/60
0.85
10
0.75
0
43
3
380-415 + N
50/60
12.7
25
0.75
12
43
3
380-415 + N
50/60
18.7
32
0.75
18
43
3 380-415
50/60 0.85 10
0.75
0
43
3 440-480
50/60 0.85
10
0.75
0
43
3 380-415
50/60 12.7 25
0.75
12 43
3 440-480
50/60 12.7 25
0.75
12 43
3 380-415
50/60 18.7 32
0.75
18 43
3 440-480
50/60 18.7 32
0.75
18 43
Table 16 – Rigid-mount machines 18 kg / 40 lb – normal spin