WORKING
CYCLE
Automatic A/C service cycle, with automatic or manual working parameter setting
NOTE: always wear safety gloves and
protection glasses when servicing an A/C
system!
You may perfom the A/C service cycle in three ways :
A)
AUTOMATIC working cycle all working phases performed in one step
B)
MANUAL working cycle single working phases performed one by one
C)
SEMI-AUTOMATIC working cycle recovery, oil drain, vacuum first step. Oil/dye and gas charging made
after the setting of the oil quantity by the user.
In all cases, there is no setting needed for the recovery phase. The vacuum/vacuum test time and the refrigerant
quantity
1.
Can be taken from the internal DATABASE or
2.
Can be defined by the user (manual setting of the parameters)
The dye quantity has to be set by the user (default is 0 g)
The new oil quantity, can be set in two ways:
1.
It can be set by the user with no regard to the the recovered oil (“MANUAL” oil setting)
2.
It can be set by the user according to the recovered quantity. In this case, the oil quantity has to be set on SA
Pressing on the DOWN button below 0 the letters SA (“SemiAutmatic”) are displayed and the unit stops after
the vacuum to allow the user to evaluate the recovered oil quntity) and set the same new oil amount.
A)
To perform an AUTOMATIC working cycle:
Choose the vehicle’s model from the
DATABASE or …
… select the AUTOMATIC CYCLE / MANUAL
PARAMETER SETTING mode (drawing at the
right) and reach the following menu
By selecting START and clicking on ENTER, the
unit performs an automatic cycle according to
the displayed parameters. In the example to
the right: 30 min vacuum, 1 min vacuum test,
10 g of new oil, 0 g of dye, 750 g refrigerant
charging .