Table 2
Unit
IN 4 XTW
IN 8 XTW
Pump level
200 °C with thermal oil
kW
17
17
8
150 °C with thermal oil
kW
17
17
8
100 °C with thermal oil
kW
10
10
8
50 °C with thermal oil
kW
2
2
8
Cooling medium
---
Water
Water
---
Connecting thread of cooling
water internal/external
Inches
G3/4“
G3/4"
---
Cooling water temperature
minimum/maximum
°C
10/30
10/30
---
Recommended cooling water
temperature
°C
15
15
---
Minimum differential pressure of
cooling water
bar
3
3
---
Maximum cooling water pres-
sure
bar
10
10
---
Maximum cooling water con-
sumption
l/min
11
11
---
If the maximum current consumption is limited
consumption” on page 101 the heating output can be reduced.
Depending on the country-specific version, the maximum current con-
sumption may already be limited ex works.
Table 3
Unit
IN 4 XTW
Heating output
‑
230 V; 50 Hz
kW
3.5
‑
200 V; 50/60 Hz
kW
2.9
‑
208-220 V; 60 Hz
kW
3.1 – 3.3
Current consumption
A
16
The mains plug for the United Kingdom (Great Britain) reduces the per-
formance data.
‑
230 V; 50 Hz
kW
2.8
Current consumption
A
13
Heating output and power supply
V6
Integral Process Thermostats and High-Temperature Thermostats
177 / 198