Instruction Manual

 

TPSRF31 (181430) - BOSS

TM

 Electronic RF Roomstat

Thank you for purchasing this product. If installing for someone else, please ensure that the 
instructions are handed to the householder.

Please read this manual prior to installation or use.

Always isolate the mains power supply before removing the unit from the backplate.

Do not mix old and new batteries. Do not use rechargeable batteries.

Please leave these instructions with the end user where they should be kept in a safe place for 
future reference.

Installation

The TPSRF31 Control Unit is easily installed using the backplate supplied. This is used purely for 
mounting, as no wiring is needed for the Control Unit. The backplate can be mounted directly to 
the wall without a back box. 

The ideal position to locate the TPSRF31 Control Unit is about 1.5m above floor level. It should be 
mounted in a location where the thermostat is accessible, reasonably lit and free from extremes of 
temperature and draughts. Do not mount the thermostat on an outside wall, above a radiator or in 
a location where it may be subjected to direct sunlight.

To ensure trouble free receiving of the Radio Frequency (RF) signal, always ensure that the 
thermostat is mounted away from any possible sources of interference (such as radio, TV sets, 
computer, etc.), the location of TPSRF31 in enclosed areas such as cellars and basements is not 
recommended, it should be positioned where the temperature sensed is representative of the zone 
being controlled.

Connecting the TPSRF31 Receiver

NOTE: All electrical installation work should be carried out by a suitably qualified Electrician or other 
competent person.

If you are not sure how to install this digital thermostat consult either with a qualified electrician, 
heating engineer or your boiler/heating system supplier for advice on how to proceed.

The TPSRF31 Receiver should be mounted in a suitable location that is both accessible for the 
connection of mains and control wiring, and allows good reception of the RF signal. The Receiver 
needs a 230V AC mains supply to operate, and this should be fused appropriately (13A max.) 
The Receiver should be mounted in a location where it will not come into contact with water, 
moisture or condensation.

The Receiver On/Off switch is accessible from the front face of the Receiver.
On the front cover of the Receiver you will see that there is the On/Off switch and two Light 
Emitting Diodes (LEDs). The switch allows you to turn off the Receiver if necessary to prevent it 
calling for heat. The top LED (orange) will illuminate when the switch is in the “On” position and 
the unit is receiving power. The bottom LED (green) illuminates when the Receiver unit is receiving 
a heat call transmission from the Control Unit.

Summary of Contents for TPSRF31

Page 1: ... as radio TV sets computer etc the location of TPSRF31 in enclosed areas such as cellars and basements is not recommended it should be positioned where the temperature sensed is representative of the zone being controlled Connecting the TPSRF31 Receiver NOTE All electrical installation work should be carried out by a suitably qualified Electrician or other competent person If you are not sure how ...

Page 2: ...ified person The installer should select the jumper positions required if changes need to be made to the factory default settings These jumpers are found on the rear of the Control Unit Jumpers Description Address code 5 DIP switch levers for 5 bits address code for RF communication All jumpers default are closed Span 3x1 pins jumper for 0 5 C or 1 0 C factory default setting selection It is used ...

Page 3: ...rs indoors however many factors can affect the RF transmission and shorten the operating distance e g shielding by thick walls foil back plasterboard metal objects such as filing cabinets general RF interference and so on The range is generally large enough for most household applications but it is advisable to test the RF transmission from the intended Control Unit location to the Receiver locati...

Page 4: ...ure setting Comf Econ Anti frost modes 1 Short press changes unit to Econ mode while in Comf mode 2 Long press for 3 seconds changes unit to Anti Frost mode while in Comf mode 3 While unit is in Anti frost mode long key press will return thermostat to its previous mode Reset To reset the thermostat Initial Power Up After power up or Reset is pressed the programmer is reset During system reset all ...

Page 5: ...ld the button for 3 seconds Once Anti Frost mode is enabled the temperature is automatically set to 5 C to provide protection from the risk of freezing Whenever Anti Frost mode is activated the Anti Frost indicator will be shown below To turn off anti frost mode press and hold the button for 3 seconds Please be aware that the Anti Frost mode operates as an additional protection feature but should ...

Page 6: ...n Model TPSRF31 Type Digital thermostat designed for Volt Free and AC heating applications Frequency 868MHz Temperature Scale C Temperature Display Range 0 0 C 35 C Displays HI if room temperature exceeds 35 C Displays Lo if room temperature below 0 0 C Temperature Display Resolution 0 5 C Temperature Setting Range 5 0 C 30 0 C 0 5 C step Temperature Setting Resolution 0 5 C Operating Temperature ...