background image

5

1) Anti-Frost mode is set at 5°C and cannot be changed.
2) Default is Comf mode after reset or power up.

View/Change set temperature mode

•  When the thermostat is in home screen in Comfort/Economy/Anti-Frost mode, press   or   to 

enter View/Change the set temperature.

• The LCD will show the current temperature setting with flashing digits.
• Press   or   again to increase or decrease the set temperature in 0.5°C steps.
• Press and Hold   or   for 2 seconds to advance quickly in is 1.0°C steps.
•  In Comfort/Economy mode, the temperature can be set between 5°C and 30°C. In Anti-Frost 

mode, the temperature is set at 5°C and cannot be changed.

• When changing temperature, only   or   have functionality. 
•  If no further keys are pressed, after 5 seconds, the setting is saved and the thermostat will return 

to home screen automatically.

Change Operation Mode

The thermostat can operate in three different modes: Comf, Econ or Anti-Frost. The default mode 
is Comf.

Change between Comf/Econ/Anti-frost mode
• Short press: changes unit from normal mode to Econ mode, or from Econ mode to normal mode.
• Long press for 3 seconds: changes unit to Anti-Frost mode from any other.
• While unit is in Anti-frost mode, a long press will return the thermostat to its previous mode

Anti-Frost Mode

To enable the anti-frost mode, press and hold the 

button for 3 seconds. Once Anti-Frost mode 

is enabled, the temperature is automatically set to 5°C to provide protection from the risk of 
freezing.
Whenever Anti-Frost mode is activated, the Anti-Frost indicator 

will be shown below.

To turn off anti-frost mode, press and hold the 

button for 3 seconds.

Please be aware that the Anti-Frost mode operates as an additional protection feature but should 
not be used in place of a correctly installed frost thermostat, which is required to override all the 
other controls in the system.

The backlight will remain illuminated for approximately 5 seconds.

Backlight

The backlight of the TPSRF31 is switched on automatically whenever any of the keys are pressed. 
The backlight will remain illuminated for approximately 5 seconds after the last key press, except 
if you are changing the set point temperature – in this case, the backlight will remain illuminated 
throughout the setting change process.

The backlight will not illuminate if the TPSRF31 battery is low.

Battery Status

•  The TPSRF31 checks the battery voltage frequently during normal operation. If the battery 

voltage is sensed as being low (this is normally when the battery voltage falls to a level of below 
2.4V, the low battery indicator 

will be displayed steadily on screen. 

•  Although the programmable thermostat will continue to operate normally at this stage, you 

should replace the batteries as soon as possible to prevent any possible operating problems.

Battery Cut-off Handling

Summary of Contents for TPSRF31

Page 1: ... as radio TV sets computer etc the location of TPSRF31 in enclosed areas such as cellars and basements is not recommended it should be positioned where the temperature sensed is representative of the zone being controlled Connecting the TPSRF31 Receiver NOTE All electrical installation work should be carried out by a suitably qualified Electrician or other competent person If you are not sure how ...

Page 2: ...ified person The installer should select the jumper positions required if changes need to be made to the factory default settings These jumpers are found on the rear of the Control Unit Jumpers Description Address code 5 DIP switch levers for 5 bits address code for RF communication All jumpers default are closed Span 3x1 pins jumper for 0 5 C or 1 0 C factory default setting selection It is used ...

Page 3: ...rs indoors however many factors can affect the RF transmission and shorten the operating distance e g shielding by thick walls foil back plasterboard metal objects such as filing cabinets general RF interference and so on The range is generally large enough for most household applications but it is advisable to test the RF transmission from the intended Control Unit location to the Receiver locati...

Page 4: ...ure setting Comf Econ Anti frost modes 1 Short press changes unit to Econ mode while in Comf mode 2 Long press for 3 seconds changes unit to Anti Frost mode while in Comf mode 3 While unit is in Anti frost mode long key press will return thermostat to its previous mode Reset To reset the thermostat Initial Power Up After power up or Reset is pressed the programmer is reset During system reset all ...

Page 5: ...ld the button for 3 seconds Once Anti Frost mode is enabled the temperature is automatically set to 5 C to provide protection from the risk of freezing Whenever Anti Frost mode is activated the Anti Frost indicator will be shown below To turn off anti frost mode press and hold the button for 3 seconds Please be aware that the Anti Frost mode operates as an additional protection feature but should ...

Page 6: ...n Model TPSRF31 Type Digital thermostat designed for Volt Free and AC heating applications Frequency 868MHz Temperature Scale C Temperature Display Range 0 0 C 35 C Displays HI if room temperature exceeds 35 C Displays Lo if room temperature below 0 0 C Temperature Display Resolution 0 5 C Temperature Setting Range 5 0 C 30 0 C 0 5 C step Temperature Setting Resolution 0 5 C Operating Temperature ...