If
Fixed Voltage
is selected,
the screen shown in
Figure 34
3. Enter the desired value within
the stated range in the provided
field.
4. Click
OK
to apply the settings.
The current
Aux Out
fixed
voltage is displayed, if
applicable.
The
Aux Out
voltage must be
between 0 V and 10 V.
4.4.3 HSU Curve
1. Click the
Settings
menu in the
upper left corner of the Main
screen and hover over
HSU
Curve
.
2. Click
Linear,
Optimized
, or
Other
as desired.
Figure 35
Load Curve
and
HSU
Parameters
are advanced
functions that should only be
accessed under direction of
Laser Mechanisms support.
4.4.4 Pressure
FiberCUT
®
2D contains a sensor to
detect changes in pressure within
the head relative to ambient
pressure.
To compensate for variations in
atmospheric pressure, calibrate
the pressure sensor daily
according to the following (see
and
):
1. Turn off and vent all gasses.
2. Click the
Settings
menu in the
upper left corner of the Main
screen, then click
Zero
Pressure
.
3. Click
OK
to confirm.