PLMNL0232 REV. H Effective Date: 01/14/19
56
FiberCUT
®
2D Operation Manual
12.2 PROFINET I/O Mapping
The GSDML file is available for download at
http://www.lasermech.com/fibercut2dupdates
SLOT
MODULE
NAME
1
Input 001 byte
Fault Digital Outs
2
Input 001 byte
Status Digital Outs
3
Input 002 bytes
HSU Voltage
4
Input 002 bytes
Process Monitor
5
Input 002 bytes
Purge Pressure
6
Input 002 bytes
Lens Position
7
Input 002 bytes
Process Monitor Temp
8
Input 002 bytes
Electronics Temp
9
Input 002 bytes
Collimator Temp
10
Input 002 bytes
Upper CG Temp
11
Input 002 bytes
Lens Temp
12
Input 002 bytes
Lower CG Temp
13
Input 002 bytes
Nozzle Temp
14
Input 002 bytes
HSU Curve
15
Input 002 bytes
Aux Out Setting
16
Input 002 bytes
Focus Position
17
Input 002 bytes
Maximum Position
18
Input 002 bytes
Process Monitor Gain
19
Output 001 byte
Config Bits
20
Output 001 byte
Command Bits
21
Output 002 bytes
Set Position
22
Output 002 bytes
Set HSU Curve
23
Output 002 bytes
Set Aux Out
24
Output 002 bytes
Set Focus Position
25
Output 002 bytes
Set Process Monitor Gain
Fault Digital Outs
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
No
Comm.
Position
Error
Temperature
Fault
Purge
Fault
Lens
Fault
HSU Fault
Status Digital Outs
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Reserved For
Future Use
Cal Ack.
Reserved for
Future Use
Lens in
Position
Lens at
Zero
TOUCH
READY
Config Bits
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Reserved For Future Use
Suppress Low
Purge Fault
Command Bits
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Reserved For Future Use
Zero
Pressure
Move
Lens
Reset
CAL
ITEM
DESCRIPTION
Device Name ABIC-PRT