PLMNL0232 REV. H Effective Date: 01/14/19
29
FiberCUT
®
2D Operation Manual
Figure 31
Click the
Disconnect
button
(top center of the Main
Screen) or the red X (upper
right corner of the Main
screen) to disconnect the
control box and head.
o
Either of these actions
will end the session.
2. Note the following displays:
The status of the head is
displayed in the upper right
corner of the Main Screen.
If the tip contacts another
surface, the indicator light
next to TIP TOUCH (lower
right of the Main screen) will
be illuminated green.
The Main screen displays
the current value of:
o
Standoff Height
o
Focus Position
o
Temperature for
electronics, both cover
glasses, process
monitor, focusing lens,
and nozzle
o
Purge gas pressure
4.3.3 Faults and Status Indicator
When a fault occurs, the
Ready
output turns off and the
corresponding light on the control
box turns red. A description of the
fault is also displayed in red in the
upper right corner of the Main
screen and the module responsible
for the fault will be highlighted on
the diagram of the head.
Faults occur when:
The HSU fails to calibrate.
A cable break occurs within the
head. For instance, if the tip
assembly is removed.
Communication between the
controller and head is lost.
A temperature goes above the
upper limit.
A cover glass door is open or
drawer is removed.
The purge pressure goes below
the lower limit (unless
suppressed) or above the upper
limit.
The lens travels outside its
allowed range or takes too long
to reach the commanded
position.