PLMNL0232 REV. H Effective Date: 01/14/19
11
FiberCUT
®
2D Operation Manual
8. Align the lower fiber clamp so:
It is centered between the
water cooled fiber interface
adapter and the fiber clamp
round base.
The (4) captive M4 SHCS
are in line with the M4
tapped holes in the fiber
clamp body.
The (2) alignment holes are
in line with the (2) alignment
pins in the fiber clamp body.
9. Tighten the (4) captive M4
SHCS loosened in step 2.
Tighten the (2) SHCS on
one side of the clamp one
turn.
Tighten the (2) SHCS on
the other side of the clamp
one turn.
Repeat the process until the
SHCS are tight on both
sides.
10. Verify the gap between the
lower fiber clamp and the fiber
clamp body is the same on both
sides of the lower fiber clamp.
Otherwise, the fiber may be
out of alignment when it is
installed.
11. Install the fiber and upper fiber